Prevention and control of emergent infectious disease with high specific antigen sensor
Abstract
This study aims to evaluate the application of a new type of high specificity antigen sensor in detecting the viruses in sudden infectious diseases. Influenza A (H1N1) virus immunosensor was used for the respective determination of the six kinds of antigens of H1N1, H3N2 viral protein, HA protein of H7N9, influenza B virus, adenovirus, and EV71 virus of same dilution degree on the Screen Printed Carbon Electrode (SPCE), so as to test the specificity of the detection method. In addition, various batches of chick embryo allantoic saliva dilution simulation samples were also detected on their recovery (accuracy), repeatability (precision), and stability. The results were as follows: the linear equation was y = 121.33x + 168; the slope of the linear equation was 121.33 nA/HA unit, representing the sensitivity; correlation coefficient was R2=0.9921 > 0.90. Using Statistical Analysis System (SAS) software, we found that: the W values of seven sets of data after Shapiro-Wilk detection were 0.853, 0.991, 0.901, 0.906, 0.825, 0.974, and 0.992, respectively; P values were 0.247, 0.831, 0.386, 0.405, 0.174, 0.691, and 0.821, respectively, all of which were greater than 0.05, suggesting that normality was met. The results of homogeneity test for variance were as follows: F = 2.44, P = 0.0775 > 0.05, suggesting that homogeneity of variance was met. The parametric test results were as follows: F = 19114.0, P < 0.0001, suggesting that there were obvious differences between testing data of the seven groups. The determination recovery rate of electrochemical immunosensor was 80-110%. Relative Standard Deviation (RSD) values of repeatability (precision) test of H1N1 influenza virus electrochemical immunosensor were 7.74%, 3.54%, and 2.01%, all of which were smaller than 10%. The signal response of H1N1 electrochemical immune biological sensor could still maintain more than 85% of the original signal within 30 days of storage. In conclusion, H1N1 electrochemical immune biosensor has good specificity and the test results are not affected by other viruses of the same type. Besides, it has good accuracy which can realize the accurate determination of A (H1N1) influenza virus in actual detection. Thus, the requirement of precision measurement of A (H1N1) flu virus detection can be met. Therefore, H1N1 electrochemical immune biosensors can be used in actual detection with good stability.
Keywords: Graphene oxide; higher specificity antigen sensor; influenza A virus; sudden infectious diseases.
Similar articles
-
Electro-Nano Diagnostic Platform Based on Antibody-Antigen Interaction: An Electrochemical Immunosensor for Influenza A Virus Detection.Biosensors (Basel). 2023 Jan 23;13(2):176. doi: 10.3390/bios13020176. Biosensors (Basel). 2023. PMID: 36831942 Free PMC article.
-
Comparative analytical sensitivities of six rapid influenza A antigen detection test kits for detection of influenza A subtypes H1N1, H3N2 and H5N1.J Clin Virol. 2007 Feb;38(2):169-71. doi: 10.1016/j.jcv.2006.11.010. Epub 2006 Dec 27. J Clin Virol. 2007. PMID: 17194622
-
Dual immunosensor based on methylene blue-electroadsorbed graphene oxide for rapid detection of the influenza A virus antigen.Talanta. 2016 Aug 1;155:250-7. doi: 10.1016/j.talanta.2016.04.047. Epub 2016 Apr 25. Talanta. 2016. PMID: 27216681
-
[Swine influenza virus: evolution mechanism and epidemic characterization--a review].Wei Sheng Wu Xue Bao. 2009 Sep;49(9):1138-45. Wei Sheng Wu Xue Bao. 2009. PMID: 20030049 Review. Chinese.
-
Electrochemical detection of viruses and antibodies: A mini review.Electrochem commun. 2020 Jul;116:106762. doi: 10.1016/j.elecom.2020.106762. Epub 2020 May 26. Electrochem commun. 2020. PMID: 32501391 Free PMC article. Review.
Cited by
-
Biosensors for the detection of respiratory viruses: A review.Talanta Open. 2020 Dec;2:100007. doi: 10.1016/j.talo.2020.100007. Epub 2020 Aug 16. Talanta Open. 2020. PMID: 34913046 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous