Decade-Long Profile of Imaging Biomarker Use in Ophthalmic Clinical Trials
- PMID: 28525561
- DOI: 10.1167/iovs.17-21790
Decade-Long Profile of Imaging Biomarker Use in Ophthalmic Clinical Trials
Abstract
Purpose: The purpose of this study was to investigate the use of imaging biomarkers in published clinical trials (CTs) in ophthalmology and its eventual changes during the past 10 years.
Methods: We sampled from published CTs in the fields of cornea, retina, and glaucoma between 2005-2006 and 2015-2016. Data collected included year of publication, phase, subspecialty, location, compliance with Consolidated Standards for Reporting Trials, impact factor, presence and use of imaging biomarkers (diagnostic, prognostic and predictive; primary and secondary surrogate endpoints), and use of centralized reading centers.
Results: We included 652 articles for analysis, equally distributed in three timeframes (2005-2006, 2010-2011, and 2015-2016), mainly reporting phase IV CTs and trials on procedures (42.2% and 35.4%, respectively). Imaging biomarkers were included in 46.3% of the analyzed CTs and their use significantly increased over time (P < 0.05). Optical coherence tomography was the most frequently used device (27.7%), whereas diagnostic biomarkers and secondary surrogate endpoints were the most frequent biomarker types (19.5% and 22.5%, respectively). Early-phase CTs showed an increase in the use of biomarkers for patient selection and stratification over time (P < 0.05), but not in the use of imaging surrogate endpoints (P = 0.90). Only 3 of 59 (5.1%) of phase III CTs included primary surrogate imaging endpoints, whereas secondary surrogate imaging endpoints were present in 50.8% of these trials (P < 0.001). Retinal CTs had the highest prevalence for each type of imaging biomarker (P < 0.001). Reading centers were used in 52 of 302 CTs (17.2%), with no significant time-related increase.
Conclusions: Imaging biomarkers are increasingly used in published CTs in ophthalmology. Additional efforts, including centralized reading centers, are needed to improve their validation and use, allowing a wider use of these tools as primary surrogate endpoints in phase III CTs.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous