. 2018 Jun;38(3):1085-1093.
doi: 10.1007/s10792-017-0564-9. Epub 2017 May 20.

Operating room fires in periocular surgery

Affiliations

Operating room fires in periocular surgery

Michael A Connor et al. Int Ophthalmol. 2018 Jun.

Abstract

Aim: A survey of ophthalmic plastic and reconstructive surgeons as well as seven-year data regarding claims made to the Ophthalmic Mutual Insurance Company (OMIC) is used to discuss operating room fires in periocular surgery.

Methods: A retrospective review of all closed claim operating room fires submitted to OMIC was performed. A survey soliciting personal experiences with operating room fires was distributed to all American Society of Oculoplastic and Reconstructive Surgeons.

Results: Over the last 2 decades, OMIC managed 7 lawsuits resulting from an operating room fire during periocular surgery. The mean settlement per lawsuit was $145,285 (range $10,000-474,994). All six patients suffered burns to the face, and three required admission to a burn unit. One hundred and sixty-eight surgeons participated in the online survey. Approximately 44% of survey respondents have experienced at least one operating room fire. Supplemental oxygen was administered in 88% of these cases. Most surgical fires reported occurred in a hospital-based operating room (59%) under monitored anesthesia care (79%). Monopolar cautery (41%) and thermal, high-temperature cautery (41%) were most commonly reported as the inciting agents. Almost half of the patients involved in a surgical fire experienced a complication from the fire (48%). Sixty-nine percent of hospital operating rooms and 66% of ambulatory surgery centers maintain an operating room fire prevention policy.

Conclusions: An intraoperative fire can be costly for both the patient and the surgeon. Ophthalmic surgeons operate in an oxygen rich and therefore flammable environment. Proactive measures can be undertaken to reduce the incidence of surgical fires periocular surgery; however, a fire can occur at any time and the entire operating room team must be constantly vigilant to prevent and manage operating room fires.

Keywords: Fire; Fires; OR fires; Operating room fires.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Plast Reconstr Surg. 1995 Apr;95(5):924-8 - PubMed
    1. ANZ J Surg. 2005 Jul;75(7):556-8 - PubMed
    1. Anesth Analg. 2001 Oct;93(4):960-5 - PubMed
    1. Arch Surg. 2006 Apr;141(4):353-7; discussion 357-8 - PubMed
    1. Jt Comm J Qual Patient Saf. 2005 Sep;31(9):522-7 - PubMed

LinkOut - more resources