The biochemical and histological effects of artificial ligament wear particles: in vitro and in vivo studies
- PMID: 2853576
- DOI: 10.1177/036354658801600602
The biochemical and histological effects of artificial ligament wear particles: in vitro and in vivo studies
Abstract
Growing evidence suggests that biochemical mechanisms play a role in the pathogenesis of arthritis. Cartilaginous wear particles have been shown to induce destructive enzymes and cytokines. To assess the biocompatibility of artificial ACL replacements, the effects of wear particles from the following ligaments were analyzed biochemically and histologically: GORETEX, Stryker Dacron Ligament Prosthesis, Versigraft carbon, Kennedy LAD, Xenograft, Leeds-Keio, and human patellar tendon allograft. Ligaments were frozen and ground to produce wear particles similar to those seen clinically and were added to lapine synovial cell cultures. The resulting conditioned medium was analyzed for collagenase, gelatinase, and chondrocyte activating factor (CAF) production. All of the ligaments induced significantly elevated enzyme and CAF production by the synoviocytes, with Xenograft and carbon inducing significantly higher enzyme levels than those of the other five ligaments. Five milligrams of wear particles were injected into the knees of 4 kg to 5 kg rabbits that were analyzed histologically after 14 weeks. Wear particles accumulated in the periarticular synovial folds and induced modest to severe macrophage infiltration in the synovium. A hypothetical model explaining the role of artificial ligament wear particles in the pathogenesis of arthritis is presented.
Similar articles
-
Experimental arthritis induced by intraarticular injection of allogenic cartilaginous particles into rabbit knees.Arthritis Rheum. 1984 Feb;27(2):200-7. doi: 10.1002/art.1780270212. Arthritis Rheum. 1984. PMID: 6320835
-
The induction of IL-1 by freeze-dried ethylene oxide-treated bone-patellar tendon-bone allograft wear particles: an in vitro study.Arthroscopy. 1993;9(1):82-6. doi: 10.1016/s0749-8063(05)80349-4. Arthroscopy. 1993. PMID: 8442836
-
Collagenases from periarticular ligaments and tendon: enzyme levels during the development of joint contracture.Matrix. 1989 Jun;9(3):200-5. doi: 10.1016/s0934-8832(89)80051-4. Matrix. 1989. PMID: 2550751
-
Biological response to ligament wear particles.J Appl Biomater. 1995 Spring;6(1):35-41. doi: 10.1002/jab.770060106. J Appl Biomater. 1995. PMID: 7703536
-
[Proteolytic enzymes and the destruction of articular cartilage in arthritis and chronic polyarthritis].Wien Med Wochenschr. 1991;141(4):77-85. Wien Med Wochenschr. 1991. PMID: 1645488 Review. German.
Cited by
-
Neotendon formation induced by manipulation of the Smad8 signalling pathway in mesenchymal stem cells.J Clin Invest. 2006 Apr;116(4):940-52. doi: 10.1172/JCI22689. J Clin Invest. 2006. PMID: 16585960 Free PMC article.
-
Revision surgery after failed ACL reconstruction with artificial ligaments: clinical, histologic and radiographic evaluation.Eur J Orthop Surg Traumatol. 2014 Jan;24(1):93-8. doi: 10.1007/s00590-012-1136-3. Epub 2012 Dec 4. Eur J Orthop Surg Traumatol. 2014. PMID: 23412261
-
Enhancing the Surface Properties of a Bioengineered Anterior Cruciate Ligament Matrix for Use with Point-of-Care Stem Cell Therapy.Engineering (Beijing). 2021 Feb;7(2):153-161. Epub 2020 May 7. Engineering (Beijing). 2021. PMID: 34136308 Free PMC article.
-
Reconstruction of the anterior cruciate ligament with carbon fibres: unsatisfactory results after 8 years.Knee Surg Sports Traumatol Arthrosc. 1996;4(3):132-6. doi: 10.1007/BF01577404. Knee Surg Sports Traumatol Arthrosc. 1996. PMID: 8961226
-
Enhancement of osseointegration of polyethylene terephthalate artificial ligament by coating of silk fibroin and depositing of hydroxyapatite.Int J Nanomedicine. 2014 Sep 29;9:4569-80. doi: 10.2147/IJN.S69137. eCollection 2014. Int J Nanomedicine. 2014. PMID: 25302023 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources