Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Jun;31(6):1525-1535.
doi: 10.1519/JSC.0000000000001312.

Proposal of a New Specific Cardiopulmonary Exercise Test for Taekwondo Athletes

Affiliations

Proposal of a New Specific Cardiopulmonary Exercise Test for Taekwondo Athletes

Marcus P Araujo et al. J Strength Cond Res. 2017 Jun.

Abstract

The objective of this study is to evaluate the cardiorespiratory variables of Taekwondo athletes while performing incremental exercise test on an ergometer using a ramp protocol and to propose a specific protocol for assessing these physiological variables during Taekwondo practice. Fourteen athletes participated in 2 incremental exercise tests: a treadmill exercise test (TREADtest) and a Taekwondo-specific exercise test (TKDtest). The TKDtest consists in 1-minute stages of kicks with an incremental load between then. The subjects perform kicks each time a sound signal was heard. Heart rate (HR), oxygen uptake (V[Combining Dot Above]O2), and their reserve correspondents (V[Combining Dot Above]O2R and reserve heart rate [HRR]) were divided into quartiles to verify their kinetics along the tests. Significant difference between 2 tests was found only for V[Combining Dot Above]O2R (p = 0.03). Regarding the quartiles, significant differences were found for HR in the first (p = 0.030) and second (p = 0.003). Analyzing the regression curves, significant differences were found for HR for intercept (p = 0.01) and slope (p = 0.05) and HRR for slope (p = 0.02). Analysis showed that significant reliability, with intraclass correlation coefficient (ICC), was found for the V[Combining Dot Above]O2peak (ICC = 0.855, p = 0.003), V[Combining Dot Above]O2 in ventilatory thresholds 1 (ICC = 0.709, p = 0.03) and 2 (ICC = 0.848, p = 0.003). Bland-Altman analyses reported a mean difference ± the 95% limits of agreement of 2.2 ± 8.4 ml·kg·min to V[Combining Dot Above]O2peak. The TKDtest is reliable for measurement of cardiorespiratory variables, and the behavior of these variables differs mainly from TREADtest, probably because of the motor task performed.

PubMed Disclaimer

LinkOut - more resources