Clinical Use of Continuous Glucose Monitoring in Adults with Type 1 Diabetes
- PMID: 28541131
- PMCID: PMC5444504
- DOI: 10.1089/dia.2017.0051
Clinical Use of Continuous Glucose Monitoring in Adults with Type 1 Diabetes
Abstract
With the emphasis on intensive management of type 1 diabetes, data from studies support frequent monitoring of glucose levels to improve glycemic control and reduce glucose variability, which can be related to an increase in macro and microvascular complications. However, few perform capillary blood glucose that frequently. There are currently two available alternatives that this review will discuss, continuous glucose monitoring (CGM) and flash glucose monitoring. CGM has become an important diagnostic and therapeutic option in optimizing diabetes management. CGM systems are now more accurate, smaller, and easier to use compared to original models. Randomized controlled trials (RCTs) have demonstrated that CGM can improve Hemoglobin A1c (HbA1C) and reduce glucose variability in both continuous subcutaneous insulin infusion and multiple daily injection users. When used in an automated "insulin-suspend" system, reduced frequency of hypoglycemia and shorter time spent in hypoglycemic range have been demonstrated. Despite the potential benefits CGM has to offer in clinical practice, concerns exist on the accuracy of these devices and patient compliance with therapy, which may prevent the true clinical benefit of CGM being achieved, as observed in RCTs. Flash glucose monitoring systems FreeStyle® Libre™ (Abbott Diabetes Care, Alameda, CA) are as accurate as many CGM systems available and have the added benefit of being factory calibrated. Studies have shown that flash glucose monitoring systems are very well tolerated by patients and effectively reduce glucose variability, increasing time in range.
Keywords: Continuous glucose monitoring; Flash glucose monitoring; Glycemic control; Hypoglycemia; Type 1 diabetes.
Figures
Similar articles
-
Switching from Flash Glucose Monitoring to Continuous Glucose Monitoring on Hypoglycemia in Adults with Type 1 Diabetes at High Hypoglycemia Risk: The Extension Phase of the I HART CGM Study.Diabetes Technol Ther. 2018 Nov;20(11):751-757. doi: 10.1089/dia.2018.0252. Epub 2018 Sep 28. Diabetes Technol Ther. 2018. PMID: 30265562 Free PMC article. Clinical Trial.
-
Effects of real-time continuous glucose monitoring in type 1 diabetes: a meta-analysis of randomized controlled trials.Acta Diabetol. 2021 Apr;58(4):401-410. doi: 10.1007/s00592-020-01589-3. Epub 2020 Aug 13. Acta Diabetol. 2021. PMID: 32789691
-
Study of MiniMed 640G Insulin Pump with SmartGuard in Prevention of Low Glucose Events in Adults with Type 1 Diabetes (SMILE): Design of a Hypoglycemia Prevention Trial with Continuous Glucose Monitoring Data as Outcomes.Diabetes Technol Ther. 2018 Nov;20(11):758-766. doi: 10.1089/dia.2018.0222. Epub 2018 Oct 16. Diabetes Technol Ther. 2018. PMID: 30325656
-
Continuous Glucose Monitoring: A Review of Recent Studies Demonstrating Improved Glycemic Outcomes.Diabetes Technol Ther. 2017 Jun;19(S3):S25-S37. doi: 10.1089/dia.2017.0035. Diabetes Technol Ther. 2017. PMID: 28585879 Free PMC article. Review.
-
Personal continuous glucose monitoring (CGM) in diabetes management: review of the literature and implementation for practical use.Diabetes Res Clin Pract. 2012 Jun;96(3):294-305. doi: 10.1016/j.diabres.2011.12.010. Epub 2011 Dec 28. Diabetes Res Clin Pract. 2012. PMID: 22209014 Review.
Cited by
-
Assessment of Patient-reported Satisfaction and Metabolic Outcomes Following Initiation of the Second Generation of Flash Glucose Monitoring in Patients with Type 1 Diabetes.Curr Diabetes Rev. 2024;20(4):e100823219628. doi: 10.2174/1573399820666230810123504. Curr Diabetes Rev. 2024. PMID: 37563819
-
Time for Using Machine Learning for Dose Guidance in Titration of People With Type 2 Diabetes? A Systematic Review of Basal Insulin Dose Guidance.J Diabetes Sci Technol. 2024 Sep;18(5):1185-1197. doi: 10.1177/19322968221145964. Epub 2022 Dec 23. J Diabetes Sci Technol. 2024. PMID: 36562599 Free PMC article.
-
The Relationship Between Hemoglobin A1c, Time in Range, and Glycemic Management Indicator in Patients With Type 1 and Type 2 Diabetes in a Tertiary Care Hospital in Saudi Arabia.Cureus. 2024 Jul 6;16(7):e63947. doi: 10.7759/cureus.63947. eCollection 2024 Jul. Cureus. 2024. PMID: 39105008 Free PMC article.
-
Patient Demographics and Clinical Outcomes Among Type 1 Diabetes Patients Using Continuous Glucose Monitors: Data From T1D Exchange Real-World Observational Study.J Diabetes Sci Technol. 2023 Mar;17(2):322-328. doi: 10.1177/19322968211049783. Epub 2021 Oct 9. J Diabetes Sci Technol. 2023. PMID: 34632823 Free PMC article.
-
Association of continuous glucose monitoring-derived time in range with major amputation risk in diabetic foot osteomyelitis patients undergoing amputation.Ther Adv Endocrinol Metab. 2022 May 18;13:20420188221099337. doi: 10.1177/20420188221099337. eCollection 2022. Ther Adv Endocrinol Metab. 2022. PMID: 35602463 Free PMC article.
References
-
- The Diabetes Control and Complications Trial Research Group, Nathan DM, Genuth S, et al. : The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Engl J Med 1993;329:977–986 - PubMed
-
- Mastrototaro J: The miniMed continuous glucose monitoring system (CGMS). J Pediatr Endocrinol Metab 1999;12:751–758 - PubMed
-
- Boyne MS, Silver DM, Kaplan J, et al. : Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor. Diabetes 2003;52:2790–2794 - PubMed
-
- Schütt M, Kern W, Krause U, et al. : Is the frequency of self-monitoring of blood glucose related to long-term metabolic control? Multicenter analysis including 24,500 patients from 191 centers in Germany and Austria. Exp Clin Endocrinol Diabetes 2006;114:384–388 - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources