Virtual Monoenergetic Imaging and Iodine Perfusion Maps Improve Diagnostic Accuracy of Dual-Energy Computed Tomography Pulmonary Angiography With Suboptimal Contrast Attenuation
- PMID: 28542094
- DOI: 10.1097/RLI.0000000000000387
Virtual Monoenergetic Imaging and Iodine Perfusion Maps Improve Diagnostic Accuracy of Dual-Energy Computed Tomography Pulmonary Angiography With Suboptimal Contrast Attenuation
Abstract
Objectives: The aim of this study was to investigate the impact of virtual monoenergetic imaging (VMI+) and dual-energy computed tomography perfusion maps (DECT-PMs) on reader confidence and diagnostic accuracy in dual-energy computed tomography pulmonary angiography (DE-CTPA) studies with suboptimal contrast attenuation, compared with standard linearly blended reconstruction series.
Materials and methods: Dual-energy computed tomography pulmonary angiography examinations with suboptimal contrast attenuation of 68 patients with suspected pulmonary embolism (PE) were included in this institutional review board-approved retrospective study. Virtual monoenergetic imaging series at 40 keV, DECT-PM, and linearly blended images (M_0.6, 60% 90-kV spectrum) were reconstructed. Contrast-to-noise ratio and signal-to-noise ratio within the pulmonary trunk were calculated. Four independent radiologists assessed the presence of PE and their diagnostic confidence using 3 DE-CTPA reconstruction protocols: protocol 1, M_0.6 images; protocol 2, M_0.6 series and DECT-PM; and protocol 3, M_0.6, DECT-PM, and VMI+ series. Receiver operating characteristic (ROC) analysis was performed.
Results: Fourteen patients showed central and 29 segmental PE. Greater contrast-to-noise ratio and signal-to-noise ratio values were measured in VMI+ series at 40 keV in comparison to M_0.6 images (P < 0.001). Diagnostic accuracy for segmental PE detection was as follows: protocol 1 (69.1%); protocol 2 (86.8%); and protocol 3 (92.6%). Protocol 3 resulted in a significantly greater area under the curve for diagnosing segmental PE (0.991, P ≤ 0.033), compared with protocol 1 and 2 (0.897 and 0.951, respectively), and provided the highest diagnostic confidence (P < 0.001).
Conclusions: A reconstruction protocol including 40-keV VMI+ series and DECT-PM improves reader confidence and diagnostic accuracy for segmental PE detection compared with standard M_0.6 images in DE-CTPA with suboptimal contrast attenuation.
Similar articles
-
Comprehensive Comparison of Virtual Monoenergetic and Linearly Blended Reconstruction Techniques in Third-Generation Dual-Source Dual-Energy Computed Tomography Angiography of the Thorax and Abdomen.Invest Radiol. 2016 Sep;51(9):582-90. doi: 10.1097/RLI.0000000000000272. Invest Radiol. 2016. PMID: 26953565
-
Effect of Noise-Optimized Monoenergetic Postprocessing on Diagnostic Accuracy for Detecting Incidental Pulmonary Embolism in Portal-Venous Phase Dual-Energy Computed Tomography.Invest Radiol. 2017 Mar;52(3):142-147. doi: 10.1097/RLI.0000000000000319. Invest Radiol. 2017. PMID: 27548345
-
A noise-optimized virtual monoenergetic reconstruction algorithm improves the diagnostic accuracy of late hepatic arterial phase dual-energy CT for the detection of hypervascular liver lesions.Eur Radiol. 2018 Aug;28(8):3393-3404. doi: 10.1007/s00330-018-5313-6. Epub 2018 Feb 19. Eur Radiol. 2018. PMID: 29460075
-
Review of Clinical Applications for Virtual Monoenergetic Dual-Energy CT.Radiology. 2019 Nov;293(2):260-271. doi: 10.1148/radiol.2019182297. Epub 2019 Sep 10. Radiology. 2019. PMID: 31502938 Review.
-
Pulmonary Embolism Versus Mimics on Dual-energy Spectral Computed Tomography: An Algorithmic Approach.J Comput Assist Tomogr. 2020 Nov/Dec;44(6):833-840. doi: 10.1097/RCT.0000000000001093. J Comput Assist Tomogr. 2020. PMID: 33196595 Review.
Cited by
-
Extra-abdominal dual-energy CT applications: a comprehensive overview.Radiol Med. 2020 Apr;125(4):384-397. doi: 10.1007/s11547-019-01126-5. Epub 2020 Jan 10. Radiol Med. 2020. PMID: 31925704 Review.
-
Prognostic Value of Dual-Energy CT-Based Iodine Quantification versus Conventional CT in Acute Pulmonary Embolism: A Propensity-Match Analysis.Korean J Radiol. 2020 Sep;21(9):1095-1103. doi: 10.3348/kjr.2019.0645. Korean J Radiol. 2020. PMID: 32691545 Free PMC article.
-
Review of Clinical Applications of Dual-Energy CT in Patients after Endovascular Aortic Repair.J Clin Med. 2023 Dec 18;12(24):7766. doi: 10.3390/jcm12247766. J Clin Med. 2023. PMID: 38137834 Free PMC article. Review.
-
Dual-Energy CT for the Detection of Portal Vein Thrombosis: Improved Diagnostic Performance Using Virtual Monoenergetic Reconstructions.Diagnostics (Basel). 2022 Jul 10;12(7):1682. doi: 10.3390/diagnostics12071682. Diagnostics (Basel). 2022. PMID: 35885585 Free PMC article.
-
Improving iodine contrast to noise ratio using virtual monoenergetic imaging and prior-knowledge-aware iterative denoising (mono-PKAID).Phys Med Biol. 2019 May 16;64(10):105014. doi: 10.1088/1361-6560/ab17fa. Phys Med Biol. 2019. PMID: 30970337 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources