Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2017 Aug;33(8):944-953.
doi: 10.1016/j.dental.2017.04.021. Epub 2017 May 22.

Durability of a low shrinkage TEGDMA/HEMA-free resin composite system in Class II restorations. A 6-year follow up

Affiliations
Randomized Controlled Trial

Durability of a low shrinkage TEGDMA/HEMA-free resin composite system in Class II restorations. A 6-year follow up

Jan W V van Dijken et al. Dent Mater. 2017 Aug.

Abstract

Objective: The objective of this randomized controlled prospective trial was to evaluate the durability of a low shrinkage and TEGDMA/HEMA-free resin composite system in posterior restorations in a 6-year follow up.

Methods: 139 Class II restorations were placed in 67 patients with a mean age of 53 years (range 29-82). Each participant received at random two, as similar as possible, Class II restorations. In the first cavity of each pair the TEGDMA/HEMA-free resin composite system was placed with its 3-step etch-and-rinse adhesive (cmf-els). In the second cavity a 1-step HEMA-free self-etch adhesive was used (AdheSe One F). The restorations were evaluated using slightly modified USPHS criteria at baseline and then yearly during 6 years. Caries risk and parafunctional habits of the participants were estimated.

Results: Three molar teeth showed mild post-operative sensitivity during 3 weeks for temperature changes and occlusal forces. After 6 years, 134 Class II restorations were evaluated. Twenty-one restorations, 8 cmf-els (11.4%) and 13 ASE-els (20%) failed during the 6 years (p<0.0001). The annual failure rates were 1.9% and 3.3%, respectively. The main reasons for failure were fracture followed by recurrent caries. Most fractures and all caries lesions were found in high risk participants.

Significance: The Class II resin composite restorations performed with the new TEGDMA/HEMA-free low shrinkage resin composite system showed good durability over six years.

Keywords: Adhesive; Clinical; HEMA; Low shrinkage; Posterior; Resin composite; TEGDMA.

PubMed Disclaimer

Publication types

LinkOut - more resources