Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
- PMID: 28570525
- PMCID: PMC5608003
- DOI: 10.3791/55632
Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Abstract
In patients with small aortic roots who need an aortic valve replacement with biological valve substitutes, the implantation of the stented pericardial valve might not meet the functional needs. The implantation of a too-small stented pericardial valve, leading to an effective orifice area indexed to a body surface area less than 0.85 cm2/m2, is regarded as prosthesis-patient mismatch (PPM). A PPM negatively affects the regression of left ventricular hypertrophy and thus the normalization of left ventricular function and the alleviation of symptoms. Persistent left ventricular hypertrophy is associated with an increased risk of arrhythmias and sudden cardiac death. In the case of predictable PPM, there are three options: 1) accept the PPM resulting from the implantation of a stented pericardial valve when comorbidities of the patient forbid the more technically demanding operative technique of implanting a larger prosthesis, 2) enlarge the aortic root to accommodate a larger stented valve substitute, or 3) implant a stentless biological valve or a homograft. Compared to classical aortic valve replacement with stented pericardial valves, the full-root implantation of stentless aortic xenografts offers the possibility of implanting a 3-4 mm larger valve in a given patient, thus allowing significant reduction in transvalvular gradients. However, a number of cardiac surgeons are reluctant to transform a classical aortic valve replacement with stented pericardial valves into the more technically challenging full-root implantation of stentless aortic xenografts. Given the potential hemodynamic advantages of stentless aortic xenografts, we have adopted full-root implantation to avoid PPM in patients with small aortic roots necessitating an aortic valve replacement. Here, we describe in detail a technique for the full-root implantation of stentless aortic xenografts, with emphasis on the management of the proximal suture line and coronary anastomoses. Limitations of this technique and alternative options are discussed.
Similar articles
-
Biological aortic valve replacement: advantages and optimal indications of stentless compared to stented valve substitutes. A review.Gen Thorac Cardiovasc Surg. 2018 May;66(5):247-256. doi: 10.1007/s11748-018-0884-3. Epub 2018 Jan 10. Gen Thorac Cardiovasc Surg. 2018. PMID: 29322433 Review.
-
Full-root aortic valve replacement with stentless xenograft achieves superior regression of left ventricular hypertrophy compared to pericardial stented aortic valves.J Cardiothorac Surg. 2015 Feb 3;10:15. doi: 10.1186/s13019-015-0219-8. J Cardiothorac Surg. 2015. PMID: 25643748 Free PMC article.
-
Stentless and stented aortic valve replacement in elderly patients: Factors affecting midterm clinical and hemodynamical outcome.Eur J Cardiothorac Surg. 2006 Nov;30(5):706-13. doi: 10.1016/j.ejcts.2006.07.017. Epub 2006 Sep 6. Eur J Cardiothorac Surg. 2006. PMID: 16950630
-
Assessing options for the small aortic root.J Heart Valve Dis. 2002 Jan;11 Suppl 1:S50-5. J Heart Valve Dis. 2002. PMID: 11843521 Review.
-
The Toronto root stentless valve in the subcoronary position is hemodynamically superior to the mosaic stented completely supra-annular bioprosthesis.J Heart Valve Dis. 2005 Nov;14(6):814-21; discussion 821. J Heart Valve Dis. 2005. PMID: 16359064
Cited by
-
Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement.J Vis Exp. 2017 Dec 11;(130):56790. doi: 10.3791/56790. J Vis Exp. 2017. PMID: 29286413 Free PMC article.
-
Biological aortic valve replacement: advantages and optimal indications of stentless compared to stented valve substitutes. A review.Gen Thorac Cardiovasc Surg. 2018 May;66(5):247-256. doi: 10.1007/s11748-018-0884-3. Epub 2018 Jan 10. Gen Thorac Cardiovasc Surg. 2018. PMID: 29322433 Review.
-
Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement.J Vis Exp. 2018 Mar 26;(133):57323. doi: 10.3791/57323. J Vis Exp. 2018. PMID: 29630054 Free PMC article.
References
-
- Bonow RO, et al. Focused update incorporated into the ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease): endorsed by the Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons. Circulation. 2008;118(15):e523–e661. - PubMed
-
- Rahimtoola SH. The problem of valve prosthesis-patient mismatch. Circulation. 1978;58(1):20–24. - PubMed
-
- Pibarot P, Dumesnil JG. Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention. J. Am. Coll. Cardiol. 2000;36(4):1131–1141. - PubMed
-
- Kang YJ. Cardiac hypertrophy: a risk factor for QT-prolongation and cardiac sudden death. Toxicol. Pathol. 2006;34(1):58–66. - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources