Prevalence of Laboratory Critical Results in Eye Patients from an Eye Hospital in Southern China
- PMID: 28573144
- PMCID: PMC5442330
- DOI: 10.1155/2017/8920350
Prevalence of Laboratory Critical Results in Eye Patients from an Eye Hospital in Southern China
Abstract
Objectives: To investigate the prevalence of laboratory critical results (CRs) and associated risk factors in patients with eye diseases in a tertiary eye hospital.
Methods: Blood samples were collected from both inpatients and outpatients at Zhongshan Ophthalmic Center, Guangzhou, China, from June 1, 2012, to May 31, 2014, and samples were sent to the hospital's clinical laboratory for blood routine, biochemistry, and blood coagulation tests. Laboratory CRs for blood glucose, sodium, potassium, white blood cell count, platelet count, prothrombin time, fibrinogen, international normalized ratio, and activated partial thromboplastin time were included in the current analysis.
Results: A total of 60403 subjects were enrolled in the current analysis. CRs were identified in 339 tests from 336 patients with a prevalence of 5.7‰. Age was positively associated with the presence of CRs. Compared to patients with lens diseases, patients with strabismus, oculoplastics, and ocular trauma were less likely to have CRs (P < 0.05), while patients with tumors were more likely to have CRs (P < 0.001).
Conclusions: The prevalence of CRs in eye patients is low but calls for medication attention. It is important for medical personnel, especially ophthalmologists, to increase awareness of the importance, as well as the prevalence and risk factors of CRs.
Figures
Similar articles
-
Evaluation of factors predictive of the prognosis in Crimean-Congo hemorrhagic fever: new suggestions.Int J Infect Dis. 2012 Feb;16(2):e89-93. doi: 10.1016/j.ijid.2011.06.005. Epub 2011 Dec 6. Int J Infect Dis. 2012. PMID: 22154082
-
Thromboelastometric (ROTEM) findings in patients suffering from isolated severe traumatic brain injury.J Neurotrauma. 2011 Oct;28(10):2033-41. doi: 10.1089/neu.2010.1744. Epub 2011 Sep 23. J Neurotrauma. 2011. PMID: 21942848
-
Pneumatic tube system transport does not alter platelet function in optical and whole blood aggregometry, prothrombin time, activated partial thromboplastin time, platelet count and fibrinogen in patients on anti-platelet drug therapy.Biochem Med (Zagreb). 2017 Feb 15;27(1):217-224. doi: 10.11613/BM.2017.023. Biochem Med (Zagreb). 2017. PMID: 28392742 Free PMC article.
-
An epidemiological and clinical study of ocular manifestations of congenital rubella syndrome in Omani children.Arch Ophthalmol. 2004 Apr;122(4):541-5. doi: 10.1001/archopht.122.4.541. Arch Ophthalmol. 2004. PMID: 15078672
-
Retrospective analyses of routine preoperative blood testing in a tertiary eye hospital: could Choosing Wisely work in China?Br J Ophthalmol. 2024 May 21;108(6):897-902. doi: 10.1136/bjo-2022-322431. Br J Ophthalmol. 2024. PMID: 37468212
Cited by
-
Prevalence, Association Relation, and Dynamic Evolution Analysis of Critical Values in Health Checkup in China: A Retrospective Study.Front Public Health. 2021 Jul 22;9:630356. doi: 10.3389/fpubh.2021.630356. eCollection 2021. Front Public Health. 2021. PMID: 34368036 Free PMC article.
-
Enhance the effectiveness of clinical laboratory critical values initiative notification by implementing a closed-loop system: A five-year retrospective observational study.J Clin Lab Anal. 2020 Feb;34(2):e23038. doi: 10.1002/jcla.23038. Epub 2019 Sep 18. J Clin Lab Anal. 2020. PMID: 31531906 Free PMC article.
-
The effect of laboratory critical value reporting on patient management at Siriraj Hospital - Thailand's largest national tertiary referral center.PLoS One. 2025 Jun 9;20(6):e0324594. doi: 10.1371/journal.pone.0324594. eCollection 2025. PLoS One. 2025. PMID: 40489494 Free PMC article.
References
-
- Lundberg G. When to panic over an abnormal value. Medical Laboratory Observer. 1972;4:47–54.
-
- The Joint Commission. Accreditation Program (2012) Laboratory, 2012 National Patient Safety Goals (NPSG.02.03.01), http://www.jointcommission.org.
-
- College of American Pathologists (2010) Laboratory General Checklist, http://www.cap.org.
-
- Chinese Medical Doctor Association. Guide for Implementation of Patient Safety Goals (in Chinese) 2009-2010. Beijing, China: Science Press; 2009.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical