Modified dynamic hip screw loaded with autologous bone graft for treating Pauwels type-3 vertical femoral neck fractures
- PMID: 28583419
- DOI: 10.1016/j.injury.2017.05.031
Modified dynamic hip screw loaded with autologous bone graft for treating Pauwels type-3 vertical femoral neck fractures
Abstract
Introduction: Management of Pauwels type-3 vertical femoral neck fractures has been a challenging clinical problem as they experience high shear forces and thus a greater risk of treatment failure. There is no apparent consensus on the optimal implant type for these injuries. We developed a modified dynamic hip screw (DHS), which was designed to a cage in the lag screw, loaded with autologous bone graft for the treatment of Pauwels type-3 vertical femoral neck fractures.
Methods: Between February 2010 and January 2012, 17 consecutive patients with Pauwels type-3 vertical femoral neck fractures were treated with the modified DHS loaded with autologous bone graft. All patients were followed up for a minimum of 24 months (range, 24-36 months). Surgical details, operative and postoperative complications, the rates of nonunion and osteonecrosis and the Harris hip score were evaluated.
Results: There were thirteen men and four women with a mean age of 37.2 years (range, 27-52 years). There were no intraoperative complications related to this technology. All fractures healed within 14.1 weeks (range, 12 to 20 weeks). One patient required total hip replacement because of avascular necrosis of the femoral head at 27 months after surgery. According to the Harris hip score, eleven patients (64.7%) had excellent results, four (23.5%) had good results, one (5.9%) had moderate and one (5.9%) had poor result.
Conclusions: The modified DHS loaded with autologous bone graft appears to be a reliable implant for the treatment of Pauwels type-3 vertical femoral neck fractures with fewer complications.
Keywords: Autologous bone graft; Dynamic hip screw; Femoral neck fractures; Fixation.
Copyright © 2017 Elsevier Ltd. All rights reserved.
Similar articles
-
[Efficacy comparison between dynamic hip screw combined with anti-rotation screw and cannulated screw in treating femoral neck fractures].Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2011 Jan;25(1):26-9. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2011. PMID: 21351604 Clinical Trial. Chinese.
-
Vertical femoral neck fractures in young adults: a closed fixation strategy using a transverse cancellous lag screw.Injury. 2017 Oct;48 Suppl 4:S10-S16. doi: 10.1016/S0020-1383(17)30769-6. Injury. 2017. PMID: 29145961
-
Medial buttress plate augmentation of cannulated screw fixation in vertically unstable femoral neck fractures: Surgical technique and preliminary results.Injury. 2017 Oct;48(10):2189-2193. doi: 10.1016/j.injury.2017.08.017. Epub 2017 Aug 9. Injury. 2017. PMID: 28818323
-
Fractures of the femoral neck: a review and personal statement.Acta Chir Orthop Traumatol Cech. 2006;73(1):45-59. Acta Chir Orthop Traumatol Cech. 2006. PMID: 16613748 Review.
-
Medial buttress plate use in neck of femur fracture fixations: A systematic review.Injury. 2025 Feb;56(2):112160. doi: 10.1016/j.injury.2025.112160. Epub 2025 Jan 12. Injury. 2025. PMID: 39827529
Cited by
-
Modified F configuration in the treatment of Pauwels type III femoral neck fracture: a finite element analysis.BMC Musculoskelet Disord. 2021 Sep 6;22(1):758. doi: 10.1186/s12891-021-04638-2. BMC Musculoskelet Disord. 2021. PMID: 34488708 Free PMC article.
-
Comparison of femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis.Biomed Eng Online. 2023 Mar 2;22(1):20. doi: 10.1186/s12938-023-01083-1. Biomed Eng Online. 2023. PMID: 36859241 Free PMC article.
-
The Risk of Avascular Necrosis Following the Stabilization of Femoral Neck Fractures: A Systematic Review and Meta-Analysis.Int J Environ Res Public Health. 2022 Aug 15;19(16):10050. doi: 10.3390/ijerph191610050. Int J Environ Res Public Health. 2022. PMID: 36011686 Free PMC article.
-
Decreased expression of long non-coding RNA SNHG7 cause recurrent spontaneous abortion through suppression proliferation and invasion of trophoblast cells via miR-34a.Am J Transl Res. 2019 Jan 15;11(1):463-472. eCollection 2019. Am J Transl Res. 2019. PMID: 30788002 Free PMC article.
-
Imaging observation of percutaneous compression plate use in promoting femoral neck fracture healing.J Int Med Res. 2021 Aug;49(8):3000605211033501. doi: 10.1177/03000605211033501. J Int Med Res. 2021. PMID: 34407688 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical