Prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp with 30mL contrast agent: An intraindividual comparison with sequential scanning at 120 kVp with 60mL contrast agent
- PMID: 28583653
- DOI: 10.1016/j.ejrad.2017.02.020
Prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp with 30mL contrast agent: An intraindividual comparison with sequential scanning at 120 kVp with 60mL contrast agent
Abstract
Purpose: To investigate image quality, radiation dose, and diagnostic efficiency of prospectively ECG-triggered high-pitch coronary CT angiography (CCTA) at 70 kVp with 30mL contrast agent intra-individually compared with routine CCTA protocol.
Materials and methods: One hundred and thirty eight patients with suspected coronary artery disease, body mass index (BMI)≤25kg/m2 and heart rate (HR)≤70 beats per minute (bpm) underwent prospectively ECG-triggered high-pitch CCTA at 70 kVp and 30mL contrast agent (protocol A) and prospectively ECG-triggered sequential scanning at 120 kVp and 60mL contrast medium (protocol B). Objective and subjective image quality, radiation doses, and diagnostic accuracy were evaluated and compared between the two protocols.
Results: Higher CT attenuation, higher noise, lower signal-to-noise ratios (SNRs) and lower contrast-to-noise ratios (CNRs) were found in protocol A than in protocol B (P<0.001). However, image quality of protocol A were diagnostic. In patients with BMI<23kg/m2 or HR<60bpm, subjective image quality scores of some coronary arteries in protocol A were not significantly different from protocol B (P>0.05). Effective dose in protocol A has reduced by 96.7% compared with protocol B (P<0.001). No significant differences were found for diagnostic accuracy between the two protocols on a per-segment (P=0.513), per-vessel (P=0.317) and per-patient (P=0.125) basis.
Conclusions: Prospectively ECG-triggered high-pitch CCTA at 70kVp with 30mL contrast agent can reduce radiation dose but maintain image quality and high diagnostic accuracy in a selected, non-obese population.
Keywords: Coronary CT angiography; Diagnostic accuracy; High-pitch acquisition; Low contrast medium; Low tube voltage; Radiation dose.
Copyright © 2017 Elsevier B.V. All rights reserved.
Similar articles
-
Image quality, radiation dose, and diagnostic accuracy of prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp in a clinical setting: comparison with invasive coronary angiography.Eur Radiol. 2016 Mar;26(3):797-806. doi: 10.1007/s00330-015-3868-z. Epub 2015 Sep 17. Eur Radiol. 2016. PMID: 26382844
-
Submillisievert coronary CT angiography with adaptive prospective ECG-triggered sequence acquisition and iterative reconstruction in patients with high heart rate on the dual-source CT.J Xray Sci Technol. 2016 Nov 22;24(6):807-820. doi: 10.3233/XST-160589. J Xray Sci Technol. 2016. PMID: 27612046 Clinical Trial.
-
Feasibility of prospectively ECG-triggered high-pitch coronary CT angiography with 30 mL iodinated contrast agent at 70 kVp: initial experience.Eur Radiol. 2014 Jul;24(7):1537-46. doi: 10.1007/s00330-014-3157-2. Epub 2014 Apr 16. Eur Radiol. 2014. PMID: 24737530
-
Low tube voltage prospectively ECG-triggered coronary CT angiography: a systematic review of image quality and radiation dose.Br J Radiol. 2018 Jul;91(1088):20170874. doi: 10.1259/bjr.20170874. Epub 2018 Mar 29. Br J Radiol. 2018. PMID: 29493261 Free PMC article.
-
Low-Dose Radiation Advances in Coronary Computed Tomography Angiography in the Diagnosis of Coronary Artery Disease.Curr Cardiol Rev. 2019;15(4):304-315. doi: 10.2174/1573403X15666190222163737. Curr Cardiol Rev. 2019. PMID: 30806322 Free PMC article. Review.
Cited by
-
Low dose contrast media in step-and-shoot coronary angiography with third-generation dual-source computed tomography: feasibility of using 30 mL of contrast media in patients with body surface area <1.7 m2.Quant Imaging Med Surg. 2021 Jun;11(6):2598-2609. doi: 10.21037/qims-20-500. Quant Imaging Med Surg. 2021. PMID: 34079726 Free PMC article.
-
Application of Low Tube Potentials in CCTA: Results From the PROTECTION VI Study.JACC Cardiovasc Imaging. 2020 Feb;13(2 Pt 1):425-434. doi: 10.1016/j.jcmg.2019.03.030. Epub 2019 Jun 12. JACC Cardiovasc Imaging. 2020. PMID: 31202772 Free PMC article.
-
Submillisievert standard-pitch CT pulmonary angiography with ultra-low dose contrast media administration: A comparison to standard CT imaging.PLoS One. 2017 Oct 18;12(10):e0186694. doi: 10.1371/journal.pone.0186694. eCollection 2017. PLoS One. 2017. PMID: 29045463 Free PMC article.
-
Influence of Contrast Agent Injection Scheme Customized by Dual-Source CT Based on Automatic Tube Voltage Technology on Image Quality and Radiation Dose of Coronary Artery Imaging.Front Surg. 2022 Apr 5;9:862697. doi: 10.3389/fsurg.2022.862697. eCollection 2022. Front Surg. 2022. PMID: 35449554 Free PMC article.
-
The ultrafast, high-pitch turbo FLASH mode of third-generation dual-source CT: Effect of different pitch and corresponding SFOV on image quality in a phantom study.J Appl Clin Med Phys. 2021 Dec;22(12):158-167. doi: 10.1002/acm2.13466. Epub 2021 Nov 9. J Appl Clin Med Phys. 2021. PMID: 34752014 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical