Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 May;29(5):874-879.
doi: 10.1589/jpts.29.874. Epub 2017 May 16.

Intra-rater and inter-rater reliability of the portable gait rhythmogram in post-stroke patients

Affiliations

Intra-rater and inter-rater reliability of the portable gait rhythmogram in post-stroke patients

Ryuji Miyata et al. J Phys Ther Sci. 2017 May.

Retraction in

Abstract

[Purpose] Gait analysis, such as portable gait rhythmogram (PGR) provides objective information that helps in the quantitative evaluation of human locomotion. The purpose of this study was to assess the reliability of PGR in post-stroke patients. [Subjects and Methods] Two raters (A and B) examined 44 post-stroke patients. To assess intra-rater reliability, rater A tested subjects on three separate occasions (Days 1, 2, and 3). To assess inter-rater reliability, raters A and B independently tested participants on the same occasion (Day 3). [Results] There was no significant systematic bias between test occasions or raters. Intraclass correlation coefficient values were 0.93-0.97 for intra-rater reliability at both the comfortable speed and maximum speed, and 0.97-0.98 (comfortable speed) and 0.87-0.99 (maximum speed) for inter-rater reliability. The standard error was 1.25-1.49 (comfortable speed) and 1.62-1.77 (maximum speed) for intra-rater investigation, and 1.04-1.32 (comfortable speed) and 0.91-1.26 (maximum speed) for inter-rater investigation. At the 90% confidence level, the minimum detectable change ranged from 2.9-4.1%, and the error of an individual's score at a given time point ranged from ±2.1-2.9%. [Conclusion] Based on this excellent reliability of the PGR in post-stroke patients, it can be recommended as a simple test of gait analysis in this population.

Keywords: Portable gait rhythmogram; Reliability; Stroke.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Beyaert C, Vasa R, Frykberg GE: Gait post-stroke: pathophysiology and rehabilitation strategies. Neurophysiol Clin, 2015, 45: 335–355. - PubMed
    1. Iosa M, Morone G, Fusco A, et al. : Seven capital devices for the future of stroke rehabilitation. Stroke Res Treat, 2012, 2012: 187965. - PMC - PubMed
    1. De Quervain IA, Simon SR, Leurgans S, et al. : Gait pattern in the early recovery period after stroke. J Bone Joint Surg Am, 1996, 78: 1506–1514. - PubMed
    1. Schutte LM, Narayanan U, Stout JL, et al. : An index for quantifying deviations from normal gait. Gait Posture, 2000, 11: 25–31. - PubMed
    1. Torricelli D, Mizanoor RS, Gonzalez J, et al. : Benchmarking human-like posture and locomotion of humanoid robots: a preliminary scheme. Biomim Biohybrid Syst, 2014, 8608: 320–331.

Publication types