Abstract
Purpose of review: To discuss the physiological significance and clinical value of dynamic preload variables in spontaneously breathing patients.
Recent findings: Dynamic preload variables reflect the response of the cardiac output to a modification of preload and can therefore be used to assess fluid responsiveness. Continuous dynamic parameters that are calculated from the variations in the arterial and plethysmographic waveforms following a mechanical breath have been shown to predict fluid responsiveness much better than static preload parameters. These parameters are displayed on many patient monitors though their use is limited to mechanically ventilated patients. However, spontaneous breathing may also induce significant hemodynamic changes because of the repetitive negative swings in the pleural pressure. By better understanding the physiological basis of these changes, the same 'dynamic parameters' can be used to gain unique physiological insights during spontaneous breathing. These include the ability to identify and/or monitor respiratory rate, respiratory effort (e.g., patient-ventilator asynchrony), fluid responsiveness (to some degree), pulsus paradoxus (e.g. asthma, cardiac tamponade), and, importantly, upper airway obstruction.
Summary: Although originally intended to be used only during mechanical ventilation, 'dynamic parameters' may offer valuable clinical information in spontaneously breathing patients.
Similar articles
-
Prediction of volume responsiveness in critically ill patients with spontaneous breathing activity.Curr Opin Crit Care. 2008 Jun;14(3):334-9. doi: 10.1097/MCC.0b013e3282fd6e1e. Curr Opin Crit Care. 2008. PMID: 18467896 Review.
-
Excessive variations in the plethysmographic waveform during spontaneous ventilation: an important sign of upper airway obstruction.Anesth Analg. 2014 Dec;119(6):1288-92. doi: 10.1213/ANE.0000000000000378. Anesth Analg. 2014. PMID: 25405690
-
Fluid responsiveness in spontaneously breathing patients: a review of indexes used in intensive care.Crit Care Med. 2005 Dec;33(12):2757-62. doi: 10.1097/01.ccm.0000189942.24113.65. Crit Care Med. 2005. PMID: 16352956 Review.
-
Passive leg raising predicts fluid responsiveness in the critically ill.Crit Care Med. 2006 May;34(5):1402-7. doi: 10.1097/01.CCM.0000215453.11735.06. Crit Care Med. 2006. PMID: 16540963
-
Prediction of fluid responsiveness in acute respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pressure.Crit Care Med. 2008 Oct;36(10):2810-6. doi: 10.1097/CCM.0b013e318186b74e. Crit Care Med. 2008. PMID: 18766099
Cited by
-
Effect of carotid corrected flow time combined with perioperative fluid therapy on preventing hypotension after general anesthesia induction in elderly patients: a prospective cohort study.Int J Surg. 2024 Feb 1;110(2):799-809. doi: 10.1097/JS9.0000000000000863. Int J Surg. 2024. PMID: 37983823 Free PMC article.