The analyzation and clinical evaluation of ECLIA and CMIA in the detection of Treponema pallidum
- PMID: 28614239
- PMCID: PMC5478324
- DOI: 10.1097/MD.0000000000007139
The analyzation and clinical evaluation of ECLIA and CMIA in the detection of Treponema pallidum
Abstract
To evaluate the clinical application value of electrochemiluminescence immunoassay analyzer (ECLIA) and chemiluminescent magnetic microparticle immunoassay (CMIA) in the detection of Treponema pallidum (TP).A total of 1225 patients in Peking University Third Hospital was enrolled from June 2014 to October 2014. ECLIA and CMIA were applied to detect the serum anti-TP. The positive rate was analyzed. RIBA was taken as a golden standard to evaluate the sensitivity, the specificity, the positive predictive value, the negative predictive value, and the accuracy of ECLIA and CMIA. A correlation analysis between 2 assays was conducted, and that between assay and RIBA. We also evaluate the clinical value of TPPA in the detection of T pallidum.The positive rate of CMIA and ECLIA is 10.63% and 9.89%, respectively, showing no statistically significant difference (P > .05). For CMIA, ECLIA, and TPPA, the sensitivity is 99.16%, 99.16%, and 99.16%, the specificity is 98.99%, 99.82%, and 100%, the positive predictive value is 91.47%, 98.33%, and 100%, the negative predictive value is 99.91%, 99.91%, and 99.91%, the coincidence rate is 99.01% (Kappa = 0.895), 99.75% (Kappa = 0.997), and 99.92% (Kappa = 0.998), respectively.The result shows high correlation between ECLIA and CMIA. Both have high sensitivity and specificity and can be used as screening tests for the diagnosis of T pallidum in common condition.
Conflict of interest statement
The authors have no conflicts of interest to disclose.
Figures
Similar articles
-
Evaluate performance of the Abbott chemiluminescent microparticle immunoassay assay for detection of syphilis infection in Chinese blood donors.J Clin Lab Anal. 2020 Jan;34(1):e23033. doi: 10.1002/jcla.23033. Epub 2019 Oct 16. J Clin Lab Anal. 2020. PMID: 31617243 Free PMC article.
-
Comparison and evaluation of Abbott chemiluminescent microparticle immunoassay and ChIVD light-initiated chemiluminescent assay in the detection of Treponema pallidum antibody.J Clin Lab Anal. 2020 Jul;34(7):e23275. doi: 10.1002/jcla.23275. Epub 2020 Mar 4. J Clin Lab Anal. 2020. PMID: 32133697 Free PMC article.
-
Consistency Between Treponema pallidum Particle Agglutination Assay and Architect Chemiluminescent Microparticle Immunoassay and Characterization of Inconsistent Samples.J Clin Lab Anal. 2015 Jul;29(4):281-4. doi: 10.1002/jcla.21765. Epub 2014 May 19. J Clin Lab Anal. 2015. PMID: 24840601 Free PMC article.
-
Comparison of performance of two Treponema pallidum automated chemiluminescent immunoassays in blood donors.Infect Dis (Lond). 2016;48(6):483-7. doi: 10.3109/23744235.2016.1142674. Epub 2016 Feb 9. Infect Dis (Lond). 2016. PMID: 27030921
-
Evaluation of three automated Treponema pallidum antibody assays for syphilis screening.J Infect Chemother. 2018 Nov;24(11):887-891. doi: 10.1016/j.jiac.2018.07.017. Epub 2018 Sep 7. J Infect Chemother. 2018. PMID: 30197093
Cited by
-
Evaluate performance of the Abbott chemiluminescent microparticle immunoassay assay for detection of syphilis infection in Chinese blood donors.J Clin Lab Anal. 2020 Jan;34(1):e23033. doi: 10.1002/jcla.23033. Epub 2019 Oct 16. J Clin Lab Anal. 2020. PMID: 31617243 Free PMC article.
-
Yield of screening blood work and MRI of the brain and orbits in the work-up of unilateral chronic optic neuropathy.Eye (Lond). 2019 Jun;33(6):974-979. doi: 10.1038/s41433-018-0326-6. Epub 2019 Feb 13. Eye (Lond). 2019. PMID: 30760894 Free PMC article.
-
Evaluation of rapid diagnostic test kits for detection of Treponema pallidum antibody.PLoS One. 2024 May 29;19(5):e0303477. doi: 10.1371/journal.pone.0303477. eCollection 2024. PLoS One. 2024. PMID: 38809884 Free PMC article.
-
Diagnostic performance of Treponema pallidum particle agglutination tests against electrochemiluminescence immunoassays for the detection of anti-TP antibodies: Evaluation study.Sex Transm Infect. 2025 Jul 17;101(5):320-324. doi: 10.1136/sextrans-2024-056298. Sex Transm Infect. 2025. PMID: 39848694 Free PMC article.
-
Comparison and evaluation of Abbott chemiluminescent microparticle immunoassay and ChIVD light-initiated chemiluminescent assay in the detection of Treponema pallidum antibody.J Clin Lab Anal. 2020 Jul;34(7):e23275. doi: 10.1002/jcla.23275. Epub 2020 Mar 4. J Clin Lab Anal. 2020. PMID: 32133697 Free PMC article.
References
-
- The Chinese Center for Disease Control and Prevention, Public Health Surveillance and Information Service Center. The Chinese A, B and C class infectious diseases epidemic dynamic introduction in December 2007. J Dis Surveil 2008;23:4.
-
- The Ministry of Health of the Chinese Syphilis Prevention and Control Planning (2010–2020). 2010. Available at: http://www.moh.gov.cn/mohbgt/s10788/201006/47778.shtml.
-
- The Ministry of Health of the 2012 Annual National Statutory Epidemic Situation of Infectious Diseases, Available at: http://www.nhfpc.gov.cn/jkj/s3578/201304/b540269c8e5141e6bb2d00ca539bb9f....
-
- Meng Z. Syphilis detection technology progress. J Clin Lab Med 2011;8:2627–8.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical