The effect of direct and indirect force transmission on peri-implant bone stress - a contact finite element analysis
- PMID: 28622020
- DOI: 10.1080/10255842.2017.1338691
The effect of direct and indirect force transmission on peri-implant bone stress - a contact finite element analysis
Abstract
In almost all finite element (FE) studies in dentistry, virtual forces are applied directly to dentures. The purpose of this study was to develop a FE model with non-linear contact simulation using an antagonist as force transmitter and to compare this with a similar model that uses direct force transmission. Furthermore, five contact situations were created in order to examine their influence on the peri-implant bone stresses, which are relevant to the survival rate of implants. It was found that the peri-implant bone stresses were strongly influenced by the kind of force transmission and contact number.
Keywords: Non-linear contact analysis; finite element analysis; occlusal loading area; peri-implant bone stress; prosthodontics.
Similar articles
-
The effect of different occlusal contact situations on peri-implant bone stress - A contact finite element analysis of indirect axial loading.Mater Sci Eng C Mater Biol Appl. 2019 Jun;99:367-373. doi: 10.1016/j.msec.2019.01.104. Epub 2019 Jan 30. Mater Sci Eng C Mater Biol Appl. 2019. PMID: 30889710
-
Effects of the implant design on peri-implant bone stress and abutment micromovement: three-dimensional finite element analysis of original computer-aided design models.J Periodontol. 2014 Sep;85(9):e333-8. doi: 10.1902/jop.2014.140107. Epub 2014 May 17. J Periodontol. 2014. PMID: 24835549
-
Biomechanical investigation of thread designs and interface conditions of zirconia and titanium dental implants with bone: three-dimensional numeric analysis.Int J Oral Maxillofac Implants. 2013 Mar-Apr;28(2):e64-71. doi: 10.11607/jomi.2131. Int J Oral Maxillofac Implants. 2013. PMID: 23527370
-
Effects of occlusal forces on the peri-implant-bone interface stability.Periodontol 2000. 2019 Oct;81(1):179-193. doi: 10.1111/prd.12291. Periodontol 2000. 2019. PMID: 31407438 Review.
-
Finite-element modeling and analysis in nanomedicine and dentistry.Nanomedicine (Lond). 2014 Aug;9(11):1681-95. doi: 10.2217/nnm.14.75. Nanomedicine (Lond). 2014. PMID: 25321169 Review.
Cited by
-
Automated Remodelling of Connectors in Fixed Partial Dentures.Dent J (Basel). 2023 Oct 27;11(11):252. doi: 10.3390/dj11110252. Dent J (Basel). 2023. PMID: 37999016 Free PMC article.
-
Effects of overdenture attachment systems with different working principles on stress transmission: A three-dimensional finite element study.J Adv Prosthodont. 2020 Dec;12(6):351-360. doi: 10.4047/jap.2020.12.6.351. Epub 2020 Dec 28. J Adv Prosthodont. 2020. PMID: 33489019 Free PMC article.
-
Comparative Numerical Analysis between Two Types of Orthodontic Wire for the Lingual Technique, Using the Finite Element Method.Appl Bionics Biomech. 2021 Mar 25;2021:6658039. doi: 10.1155/2021/6658039. eCollection 2021. Appl Bionics Biomech. 2021. PMID: 33833825 Free PMC article.
-
Finite Element Analysis of effect of cusp inclination and occlusal contacts in PFM and PEEK implant-supported crowns on resultant stresses.Med J Armed Forces India. 2022 Jan;78(1):80-87. doi: 10.1016/j.mjafi.2020.11.014. Epub 2021 Jan 16. Med J Armed Forces India. 2022. PMID: 35035048 Free PMC article.
-
Numerical Analysis of Masticatory Forces on a Lower First Molar considering the Contact between Dental Tissues.Appl Bionics Biomech. 2018 Apr 10;2018:4196343. doi: 10.1155/2018/4196343. eCollection 2018. Appl Bionics Biomech. 2018. PMID: 29849758 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources