Abstract
Background: The anterior rotator cable is critical in force transmission of the rotator cuff. However, few clinical studies have examined the correlation between the integrity of the anterior supraspinatus tendon and surgical outcomes in patients with rotator cuff tears.
Purpose: To compare the clinical and structural outcomes of the arthroscopic repair of full-thickness rotator cuff tears with and without anterior disruption of the supraspinatus tendon.
Study design: Cohort study; Level of evidence, 3.
Methods: One hundred eighty-one shoulders available for magnetic resonance imaging (MRI) at least 6 months after arthroscopic rotator cuff repair, with a minimum 1-year follow-up, were enrolled. The anterior attachment of the rotator cable was disrupted in 113 shoulders (group A) and intact in 68 shoulders (group B). The mean age at the time of surgery in groups A and B was 59.6 and 59.2 years, respectively, and the mean follow-up period was 24.2 and 25.1 months, respectively.
Results: There were statistically significant differences in the preoperative tear size and pattern and muscle fatty degeneration between the 2 groups ( P = .004, P = .008, and P < .001, respectively). At final follow-up, the mean visual analog scale (VAS) for pain score during motion was 1.31 ± 0.98 and 1.24 ± 0.90 in groups A and B, respectively ( P = .587). The mean Constant score was 77.5 ± 11.2 and 78.0 ± 11.9 points in groups A and B, respectively ( P = .875). The mean University of California, Los Angeles score was 30.5 ± 4.1 and 31.0 ± 3.0 points in groups A and B, respectively ( P = .652). In assessing the repair integrity on postoperative MRI, the retear rate was 23.9% and 14.7% in groups A and B, respectively ( P = .029).
Conclusion: Irrespective of involvement in the anterior attachment of the rotator cable, the mean 24-month follow-up demonstrated excellent pain relief and improvement in the ability to perform activities of daily living after arthroscopic rotator cuff repair. However, tears with anterior disruption of the rotator cable showed a significantly larger and more complex tear pattern and more advanced fatty degeneration. Additionally, the retear rate was significantly higher in patients with a tear involving the anterior attachment of the rotator cable.
Keywords: arthroscopic repair; retear; rotator cable; rotator cuff tear; shoulder; treatment outcome.
Similar articles
-
Arthroscopic rotator cuff repair using a suture bridge technique: is the repair integrity actually maintained?Am J Sports Med. 2011 Oct;39(10):2108-16. doi: 10.1177/0363546510397171. Epub 2011 Feb 24. Am J Sports Med. 2011. PMID: 21350064
-
Anterior rotator cable disruption does not affect outcomes in rotator cuff tear with subscapularis involvement.Knee Surg Sports Traumatol Arthrosc. 2021 Jan;29(1):154-161. doi: 10.1007/s00167-020-05891-z. Epub 2020 Feb 13. Knee Surg Sports Traumatol Arthrosc. 2021. PMID: 32055877
-
A Rotator Cuff Tear Concomitant With Shoulder Stiffness Is Associated With a Lower Retear Rate After 1-Stage Arthroscopic Surgery.Am J Sports Med. 2018 Jul;46(8):1909-1918. doi: 10.1177/0363546518768813. Epub 2018 May 14. Am J Sports Med. 2018. PMID: 29757693
-
A Systematic Review of Long-term Clinical and Radiological Outcomes of Arthroscopic and Open/Mini-open Rotator Cuff Repairs.Am J Sports Med. 2023 Jun;51(7):1904-1913. doi: 10.1177/03635465211073332. Epub 2022 Feb 18. Am J Sports Med. 2023. PMID: 35179393
-
Repair of Rotator Cuff Tears in the Elderly: Does It Make Sense? A Systematic Review.Am J Sports Med. 2020 Mar;48(3):744-753. doi: 10.1177/0363546519834574. Epub 2019 Apr 30. Am J Sports Med. 2020. PMID: 31038992
Cited by
-
Satisfactory functional and structural outcomes of anterior cable reconstruction using the proximal biceps tendon for large retracted rotator cuff tears.Knee Surg Sports Traumatol Arthrosc. 2023 May;31(5):1910-1918. doi: 10.1007/s00167-022-07112-1. Epub 2022 Aug 16. Knee Surg Sports Traumatol Arthrosc. 2023. PMID: 35974193
-
A Technique for a Suture-Based Cable Reconstruction of an Irreparable Posterosuperior Rotator Cuff Tear.Arthrosc Tech. 2022 Oct 20;11(11):e2055-e2060. doi: 10.1016/j.eats.2022.08.003. eCollection 2022 Nov. Arthrosc Tech. 2022. PMID: 36457380 Free PMC article.
-
Biceps-incorporating rotator cuff repair with footprint medialization in large-to-massive rotator cuff tears.Knee Surg Sports Traumatol Arthrosc. 2022 Jun;30(6):2113-2122. doi: 10.1007/s00167-021-06829-9. Epub 2022 Jan 6. Knee Surg Sports Traumatol Arthrosc. 2022. PMID: 34988632
-
Rotator cable and rotator interval: anatomy, biomechanics and clinical importance.EFORT Open Rev. 2019 Feb 20;4(2):56-62. doi: 10.1302/2058-5241.4.170071. eCollection 2019 Feb. EFORT Open Rev. 2019. PMID: 30931149 Free PMC article. Review.
-
Distance between the supraspinatus and long head of the biceps tendon on sagittal MRI: a new tool to identify anterior supraspinatus insertion injury.J Exp Orthop. 2021 Nov 25;8(1):108. doi: 10.1186/s40634-021-00410-6. J Exp Orthop. 2021. PMID: 34821972 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical