SBS symptoms in relation to dampness and ventilation in inspected single-family houses in Sweden
- PMID: 28624972
- PMCID: PMC5583400
- DOI: 10.1007/s00420-017-1233-z
SBS symptoms in relation to dampness and ventilation in inspected single-family houses in Sweden
Abstract
Purpose: To investigate the relationships between symptoms compatible with the sick building syndrome (SBS) in adults and building dampness and ventilation in single-family houses.
Methods: Within the Swedish BETSI study, a national sample of single-family houses were inspected by professional building experts, and adults living in the houses answered a questionnaire on SBS. Relationships between building factors and SBS were analysed using logistic regression.
Results: Of the respondents, 23% reported having had weekly SBS symptoms during the last three months. A large proportion of houses exhibited building or construction problems. In total, 40% of houses had dampness problems in the foundation, and this was related to a higher prevalence of both mucous and dermal symptoms, and any SBS symptoms. Furthermore, high air humidity was related to more symptoms, with the relationship with absolute humidity being stronger than that with relative humidity or moisture load. Symptoms were also more prevalent in houses with a high U value, reflecting a poor thermal insulation. Compared to natural ventilation, living in a house with mechanical supply and exhaust ventilation was related to a lower prevalence of general symptoms and any SBS symptoms, but there were only weak associations between measured air exchange rate and symptoms.
Conclusions: A large proportion of single-family houses have dampness problems in the foundation, and pollutants may enter the living space of the house and affect the health of the occupants. Furthermore, absolute air humidity should be measured more often in indoor air studies.
Keywords: Absolute air humidity; Concrete slab; Crawl space; Mould; SBS symptoms; U value.
Conflict of interest statement
Conflict of interest
The authors declare that they have no conflict of interest with respect to the research, authorship and/or publication of this article.
Informed consent
Informed consent was obtained from all individual participants included in the study. An information letter sent together with the questionnaire stated that if the subjects answered and returned the questionnaire it meant they had given informed consent.
Similar articles
-
Sick building syndrome in relation to building dampness in multi-family residential buildings in Stockholm.Int Arch Occup Environ Health. 2001 May;74(4):270-8. doi: 10.1007/s004200000218. Int Arch Occup Environ Health. 2001. PMID: 11401019
-
Outdoor air pollution, meteorological conditions and indoor factors in dwellings in relation to sick building syndrome (SBS) among adults in China.Sci Total Environ. 2016 Aug 1;560-561:186-96. doi: 10.1016/j.scitotenv.2016.04.033. Epub 2016 Apr 19. Sci Total Environ. 2016. PMID: 27101454
-
Asthma symptoms in relation to building dampness and odour in older multifamily houses in Stockholm.Int J Tuberc Lung Dis. 2001 May;5(5):468-77. Int J Tuberc Lung Dis. 2001. PMID: 11336279
-
[New Scientific Evidence-based Public Health Guidelines and Practical Manual for Prevention of Sick House Syndrome].Nihon Eiseigaku Zasshi. 2018;73(2):116-129. doi: 10.1265/jjh.73.116. Nihon Eiseigaku Zasshi. 2018. PMID: 29848862 Review. Japanese.
-
Summary of human responses to ventilation.Indoor Air. 2004;14 Suppl 7:102-18. doi: 10.1111/j.1600-0668.2004.00279.x. Indoor Air. 2004. PMID: 15330778 Review.
Cited by
-
AWMF mold guideline "Medical clinical diagnostics for indoor mold exposure" - Update 2023 AWMF Register No. 161/001.Allergol Select. 2024 May 3;8:90-198. doi: 10.5414/ALX02444E. eCollection 2024. Allergol Select. 2024. PMID: 38756207 Free PMC article.
-
Building and indoor environmental quality assessment of Nigerian primary schools: A pilot study.Indoor Air. 2019 May;29(3):510-520. doi: 10.1111/ina.12547. Epub 2019 Mar 20. Indoor Air. 2019. PMID: 30807666 Free PMC article.
-
Identification of MVOCs Produced by Coniophora puteana and Poria placenta Growing on WPC Boards by Using Subtraction Mass Spectra.Int J Environ Res Public Health. 2019 Jul 13;16(14):2499. doi: 10.3390/ijerph16142499. Int J Environ Res Public Health. 2019. PMID: 31337007 Free PMC article.
-
Lifestyle behaviors and home and school environment in association with sick building syndrome among elementary school children: a cross-sectional study.Environ Health Prev Med. 2020 Jul 11;25(1):28. doi: 10.1186/s12199-020-00869-2. Environ Health Prev Med. 2020. PMID: 32652952 Free PMC article.
-
Children's Respiratory Infections in Tianjin Area, China: Associations with Home Environments and Lifestyles.Int J Environ Res Public Health. 2020 Jun 7;17(11):4069. doi: 10.3390/ijerph17114069. Int J Environ Res Public Health. 2020. PMID: 32517360 Free PMC article.
References
-
- Andersson K. Epidemiological approach to indoor air problems. Indoor Air Suppl. 1998;4:32–39. doi: 10.1111/j.1600-0668.1998.tb00005.x. - DOI
-
- Andersson K, Stridh G, Fagerlund I, Larsson B. The MM-Questionnaires—a tool when solving indoor climate problems. Örebro: Occupational and Environmental Medicine, Örebro Medical Center Hospital; 1993.
-
- Araki A, Kawai T, Eitaki Y, Kanazawa A, Morimoto K, Nakayama K, Shibata E, Tanaka M, Takigawa T, Yoshimura T, Chikara H, Saijo Y, Kishi R. Relationship between selected indoor volatile organic compounds, so called microbial VOC, and the prevalence of mucous membrane symptoms in single family homes. Sci Total Environ. 2010;408(10):2208–2215. doi: 10.1016/j.scitotenv.2010.02.012. - DOI - PubMed
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources