Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Jul-Aug;56(4):776-782.
doi: 10.1053/j.jfas.2017.02.018.

Bioabsorbable Calcaneo-Stop Implant for the Treatment of Flexible Flatfoot: A Retrospective Cohort Study at a Minimum Follow-Up of 4 Years

Affiliations

Bioabsorbable Calcaneo-Stop Implant for the Treatment of Flexible Flatfoot: A Retrospective Cohort Study at a Minimum Follow-Up of 4 Years

Sandro Giannini et al. J Foot Ankle Surg. 2017 Jul-Aug.

Abstract

Arthroereisis of the subtalar joint is a common surgical technique in Europe for the management of flexible flatfoot in the pediatric population. In most cases, it is performed using a calcaneo-stop metallic screw. Despite the good clinical results, screw removal is always advised after 2 to 3 years. The use of a bioabsorbable screw might overcome the need for a second operation to remove a nonabsorbable device. We report the results of a biodegradable calcaneo-stop screw at a minimum of 4 years of follow-up. Eighty-eight procedures were performed on 44 children. All patients were clinically and radiologically evaluated preoperatively and at a minimum 4-year follow-up period. Patient satisfaction and plantar collapse using Viladot's classification were recorded. Meary's talus-first metatarsal angle and talocalcaneal angle were measured on radiographs preoperatively and at the last follow-up visit. The presence of the device at the last follow-up examination was assessed by magnetic resonance imaging. The mean follow-up duration was 56 months. Of the 44 patients, 33 (75%) reported excellent clinical outcomes, 9 (20.5%) good outcomes, and 2 (4.5%) poor. Foot print improvement was registered for all patients. The mean Meary's talus-first metatarsal angle had improved from 160.6° ± 7.7° preoperatively to 170.6° ± 6.5° at the last follow-up visit (p < .001). The talocalcaneal angle had decreased from 39.9° ± 5.2° preoperatively to 29.4° ± 4° at the last follow-up examination (p < .001). At the 4-year follow-up point, the implant could be seen to have almost completely biodegraded on magnetic resonance imaging. Two screw breakages occurred. The bioabsorbable calcaneo-stop screw seems to be an effective solution for flexible flatfoot in pediatric patients. Also, owing to its biodegradable composition, the need of a second operation for implant removal will not always be necessary.

Keywords: arthroereisis; pediatric; pes valgus; subtalar joint.

PubMed Disclaimer

LinkOut - more resources