Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Aug;409(21):4959-4969.
doi: 10.1007/s00216-017-0437-0. Epub 2017 Jun 20.

A high throughput targeted and non-targeted method for the analysis of microcystins and anatoxin-A using on-line solid phase extraction coupled to liquid chromatography-quadrupole time-of-flight high resolution mass spectrometry

Affiliations

A high throughput targeted and non-targeted method for the analysis of microcystins and anatoxin-A using on-line solid phase extraction coupled to liquid chromatography-quadrupole time-of-flight high resolution mass spectrometry

Xavier Ortiz et al. Anal Bioanal Chem. 2017 Aug.

Abstract

Microcystins are cyclic heptapeptide hepatotoxins produced by cyanobacteria in freshwater. Sample preparation for the analysis of these cyanotoxins in water from algal blooms can take up to several days due to the matrix complexity and the low detection limits required to comply with current legislation. Moreover, there is a large number of unknown microcystins that could potentially exist in the environment resulting from different amino acid substitutions into the microcystin skeletal structure. To tackle these problems, the present study involved the development of a high throughput method based on on-line solid phase extraction coupled to liquid chromatography that could provide quantitative results for 12 microcystin variants (LR, YR, RR, HtyR, HilR, WR, LW, LA, LF, LY, Dha7-LR, and Dha7-RR) and anatoxin-A in less than 3 h with detection limits between 0.004 and 0.01 μg L-1 and expanded uncertainty between 4 and 14%. Data-dependent acquisition was employed for the non-targeted analysis of these cyanotoxins. Filtering the data based on structure diagnostic fragments, two unknown microcystin variants not previously reported in the literature were detected. The structures Leu1-microcystin-Met(O)R and Leu1-microcystin-LY were fully characterized by accurate mass measurement, collision-induced dissociation, and fragmentation prediction software.

Keywords: Anatoxin-A; Data-dependent acquisition; High throughput; Microcystins; Non-targeted; On-line SPE.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources