IGRT and motion management during lung SBRT delivery
- PMID: 28647449
- DOI: 10.1016/j.ejmp.2017.06.006
IGRT and motion management during lung SBRT delivery
Abstract
Patient motion can cause misalignment of the tumour and toxicities to the healthy lung tissue during lung stereotactic body radiation therapy (SBRT). Any deviations from the reference setup can miss the target and have acute toxic effects on the patient with consequences onto its quality of life and survival outcomes. Correction for motion, either immediately prior to treatment or intra-treatment, can be realized with image-guided radiation therapy (IGRT) and motion management devices. The use of these techniques has demonstrated the feasibility of integrating complex technology with clinical linear accelerator to provide a higher standard of care for the patients and increase their quality of life.
Keywords: IGRT; Lung cancer; Motion management; Stereotactic radiotherapy.
Copyright © 2017 Associazione Italiana di Fisica Medica. All rights reserved.
Similar articles
-
ExacTrac Snap Verification: a new tool for ensuring quality control for lung stereotactic body radiation therapy.Int J Radiat Oncol Biol Phys. 2013 Jan 1;85(1):e89-94. doi: 10.1016/j.ijrobp.2012.09.020. Epub 2012 Nov 1. Int J Radiat Oncol Biol Phys. 2013. PMID: 23122980
-
Optimization and quality assurance of an image-guided radiation therapy system for intensity-modulated radiation therapy radiotherapy.Med Dosim. 2012 Autumn;37(3):321-33. doi: 10.1016/j.meddos.2011.11.006. Epub 2012 Mar 13. Med Dosim. 2012. PMID: 22417899
-
Optimizing dual-energy x-ray parameters for the ExacTrac clinical stereoscopic imaging system to enhance soft-tissue imaging.Med Phys. 2017 Mar;44(3):823-831. doi: 10.1002/mp.12093. Epub 2017 Feb 21. Med Phys. 2017. PMID: 28060412
-
MRI-guided lung SBRT: Present and future developments.Phys Med. 2017 Dec;44:139-149. doi: 10.1016/j.ejmp.2017.02.003. Epub 2017 Feb 24. Phys Med. 2017. PMID: 28242140 Review.
-
Current radiotherapy techniques in NSCLC: challenges and potential solutions.Expert Rev Anticancer Ther. 2020 May;20(5):387-402. doi: 10.1080/14737140.2020.1760094. Epub 2020 May 13. Expert Rev Anticancer Ther. 2020. PMID: 32321330 Review.
Cited by
-
Motion Management in a Patient With Tracheostomy During Lung Stereotactic Body Radiation Therapy: Breath Hold Is Worth a Try.Adv Radiat Oncol. 2022 Jan 15;7(3):100895. doi: 10.1016/j.adro.2022.100895. eCollection 2022 May-Jun. Adv Radiat Oncol. 2022. PMID: 35198840 Free PMC article. No abstract available.
-
Application of respiratory motion management technology for patients with lung cancer treated with stereotactic body radiotherapy (Review).Oncol Lett. 2025 Jun 27;30(3):415. doi: 10.3892/ol.2025.15161. eCollection 2025 Sep. Oncol Lett. 2025. PMID: 40630710 Free PMC article. Review.
-
Lung Stereotactic Body Radiation Therapy (SBRT) dose gradient and PTV volume: a retrospective multi-center analysis.Radiat Oncol. 2019 Sep 3;14(1):162. doi: 10.1186/s13014-019-1334-9. Radiat Oncol. 2019. PMID: 31481089 Free PMC article.
-
Effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 MV flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique.J Radiat Res. 2020 Jul 6;61(4):575-585. doi: 10.1093/jrr/rraa026. J Radiat Res. 2020. PMID: 32367109 Free PMC article.
-
Ten-Year Experience of Stereotactic Body Radiotherapy at a Single Institution: Impact of Technological Development on the Outcome of Patients With Early Lung Cancer.Technol Cancer Res Treat. 2020 Jan-Dec;19:1533033820979163. doi: 10.1177/1533033820979163. Technol Cancer Res Treat. 2020. PMID: 33267715 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical