. 2017 Aug;32(6):1417-1422.
doi: 10.1007/s10103-017-2265-z. Epub 2017 Jun 26.

Clinical evaluation of near-infrared light transillumination in approximal dentin caries detection

Affiliations

Clinical evaluation of near-infrared light transillumination in approximal dentin caries detection

Gokhan Ozkan et al. Lasers Med Sci. 2017 Aug.

Abstract

The objective of this clinical study was to compare conventional caries detection techniques, pen-type laser fluorescence device, and near-infrared light transillumination method in approximal dentin caries lesions. The study included 157 patients, aged 12-18, without any cavity in the posterior teeth. Two calibrated examiners carried out the assessments of selected approximal caries sites independently. After the assessments, the unopened sites were excluded and a total of 161 approximal sites were included in the study. When both the examiners arrived at a consensus regarding the presence of dentin caries, the detected lesions were opened with a conical diamond burr, the cavity extent was examined and validated (gold standard). Sensitivity, specificity, negative predictive value, positive predictive value, accuracy, and area under the ROC curve (Az) values among the caries detection methods were calculated. Bitewing radiography and near-infrared (NIR) light transillumination methods showed the highest sensitivity (0.83-0.82) and accuracy (0.82-0.80) among the methods. Visual inspection showed the lowest sensitivity (0.54). Laser fluorescence device and visual inspection showed nearly equal performance. Near-infrared light transillumination can be used as an alternative method to approximal dentin caries detection. Visual inspection and laser fluorescence device alone should not be used for approximal dentin caries.

Keywords: Caries detection; Laser fluorescence; NILT; Non-cavitated caries lesions.

PubMed Disclaimer

References

    1. J Dent. 2006 Nov;34(10 ):727-39 - PubMed
    1. Compend Contin Educ Dent. 2003 Dec;24(12):935-48; quiz 949 - PubMed
    1. Quintessence Int. 2014 Jun;45(6):531-8 - PubMed
    1. J Dent. 2010 Dec;38(12):1019-26 - PubMed
    1. Caries Res. 1997;31(3):224-31 - PubMed

Publication types

LinkOut - more resources