Inadequate pelvic radiographs: implications of not getting it right the first time
Abstract
Introduction Pelvic radiography is a frequent investigation. European guidelines aim to ensure appropriate use and adequate quality. When initial images are inadequate, repeat radiographs are often required, which may have significant patient safety and economic implications. Objectives The study aimed to assess the adequacy of pelvic imaging across three orthopaedic centres, to identify causes for inadequate imaging and to establish the cost of inadequate imaging from financial and patient safety perspectives. Methods Pelvic radiographs were identified on Picture Archiving and Communication System software at three UK hospitals. Radiographs were assessed against European guidelines and indications for repeat imaging were analysed. Results A total of 1,531 sequential pelvic radiographs were reviewed. The mean age of patients was 60 years (range 5 months to 101 years). Of this total, 51.9% of images were suboptimal, with no significant difference across the three hospitals (P > 0.05). Hospital 3 repeated radiographs in 6.3% of cases, compare with 18.1% and 19.7% at hospitals 1 and 2, respectively (P > 0.05). Hospital 3 identified pathology missed on the initial radiograph in 1% of cases, compared with 5.4% and 5.5% at hospitals 1 and 2, respectively (P > 0.05). Out-of-hours imaging is associated with a higher rate of suboptimal quality (69.1%) compared with normal working hours (51.3%; P = 0.006). Adequacy rates vary with age (χ 2 = 43.62, P < 0.001). Risk of having a suboptimal radiograph increases above the age of 60-years (χ 2 = 4.45, P < 0.05). The annual cost of repeat radiographs was £56,200 per hospital. Discussion and conclusion High rates of pelvic radiograph inadequacy can lead to missed pathology and the requirement for repeat imaging, which has significant patient safety and financial implications. Risk factors for inadequate radiographs include older patients and those having out-of-hours imaging.
Keywords: Economics; Orthopaedics; Patient safety; Pelvis.
Figures
References
-
- Department of Health The Ionising Radiation (Medical Exposure) Regulations 2000 (together with notes on good practice). London: Department of Health; 2007.
-
- Balonov MI, Shrimpton PC. Effective dose and risks from medical x-ray procedures. Ann ICRP 2012; (3–4): 129–141. - PubMed
-
- Council Directive 84/466/Euratom of 3 September 1984 laying down basic measures for the radiation protection of persons undergoing medical examination or treatment Off J Eur Communities 1984; http://eur-lex.europa.eu/legal-content/EN/TXT/?uri=OJ:L:1984:265:TOC (accessed 3 May 2017).
-
- Oestreich AE. RSNA centennial article: ALARA 1912: ‘As low a dose as possible’ a century ago. Radiographics 2014; : 1,457–1,460. - PubMed
-
- Directorate-General XII: Science, Research and Development European Guidelines on Quality Criteria for Diagnostic Radiographic Images. (EUR 16260 EN) Luxembourg: Office for Official Publications of the European Union; 1996.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources