Preliminary Clinical Application of Removable Partial Denture Frameworks Fabricated Using Computer-Aided Design and Rapid Prototyping Techniques
- PMID: 28697204
- DOI: 10.11607/ijp.5270
Preliminary Clinical Application of Removable Partial Denture Frameworks Fabricated Using Computer-Aided Design and Rapid Prototyping Techniques
Abstract
Purpose: The aim of this study was to explore the application of computer-aided design and rapid prototyping (CAD/RP) for removable partial denture (RPD) frameworks and evaluate the fitness of the technique for clinical application.
Materials and methods: Three-dimensional (3D) images of dentition defects were obtained using a lab scanner. The RPD frameworks were designed using commercial dental software and manufactured using selective laser melting (SLM). A total of 15 cases of RPD prostheses were selected, wherein each patient received two types of RPD frameworks, prepared by CAD/RP and investment casting. Primary evaluation of the CAD/RP framework was performed by visual inspection. The gap between the occlusal rest and the relevant rest seat was then replaced using silicone, and the specimens were observed and measured. Paired t test was used to compare the average thickness and distributed thickness between the CAD/RP and investment casting frameworks. Analysis of variance test was used to compare the difference in thickness among different zones.
Results: The RPD framework was designed and directly manufactured using the SLM technique. CAD/RP frameworks may meet the clinical requirements with satisfactory retention and stability and no undesired rotation. Although the average gap between the occlusal rest and the corresponding rest seat of the CAD/RP frameworks was slightly larger than that of the investment casting frameworks (P < .05), it was acceptable for clinical application.
Conclusion: RPD frameworks can be designed and fabricated directly using digital techniques with acceptable results in clinical application.
Similar articles
-
[Computer aided design and manufacture of the removable partial denture framework].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2010 Feb;27(1):170-3. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2010. PMID: 20337047 Chinese.
-
A preliminary report of designing removable partial denture frameworks using a specifically developed software package.Int J Prosthodont. 2010 Jul-Aug;23(4):370-5. Int J Prosthodont. 2010. PMID: 20617229
-
[A preliminary study on the forming quality of titanium alloy removable partial denture frameworks fabricated by selective laser melting].Zhonghua Kou Qiang Yi Xue Za Zhi. 2017 Jun 9;52(6):351-354. doi: 10.3760/cma.j.issn.1002-0098.2017.06.006. Zhonghua Kou Qiang Yi Xue Za Zhi. 2017. PMID: 28613056 Chinese.
-
Fit Accuracy of Removable Partial Denture Frameworks Fabricated with CAD/CAM, Rapid Prototyping, and Conventional Techniques: A Systematic Review.Biomed Res Int. 2021 Sep 6;2021:3194433. doi: 10.1155/2021/3194433. eCollection 2021. Biomed Res Int. 2021. PMID: 34532499 Free PMC article.
-
Accuracy of CAD-CAM systems for removable partial denture framework fabrication: A systematic review.J Prosthet Dent. 2021 Feb;125(2):241-248. doi: 10.1016/j.prosdent.2020.01.003. Epub 2020 Mar 5. J Prosthet Dent. 2021. PMID: 32147252
Cited by
-
Rehabilitation of a maxillectomy patient using intraoral scanning impression technology and a computer-aided design/computer-aided manufacturing fabricated obturator prosthesis: A clinical report.J Indian Prosthodont Soc. 2018 Jul-Sep;18(3):282-287. doi: 10.4103/jips.jips_14_18. J Indian Prosthodont Soc. 2018. PMID: 30111919 Free PMC article.
-
Accuracy of intraoral scanning methods for maxillary Kennedy class I arch.J Dent Sci. 2023 Apr;18(2):747-753. doi: 10.1016/j.jds.2022.12.006. Epub 2022 Dec 17. J Dent Sci. 2023. PMID: 37021235 Free PMC article.
-
Total digital workflow in the fabrication of a partial removable dental prostheses: A case report.SAGE Open Med Case Rep. 2019 Aug 17;7:2050313X19871131. doi: 10.1177/2050313X19871131. eCollection 2019. SAGE Open Med Case Rep. 2019. PMID: 31452892 Free PMC article.
-
Fit accuracy in the rest region of RPDs fabricated by digital technologies and conventional lost-wax casting: a systematic review and meta-analysis.BMC Oral Health. 2023 Sep 15;23(1):667. doi: 10.1186/s12903-023-03348-6. BMC Oral Health. 2023. PMID: 37715159 Free PMC article.
-
Dental Mesenchymal Stem Cell-Based Translational Regenerative Dentistry: From Artificial to Biological Replacement.Front Bioeng Biotechnol. 2018 May 2;6:49. doi: 10.3389/fbioe.2018.00049. eCollection 2018. Front Bioeng Biotechnol. 2018. PMID: 29770323 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous