Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2017 Jul/Aug;30(4):384-389.
doi: 10.11607/ijp.5078.

Comparison of Clinical, Radiographic, and Immunologic Inflammatory Parameters Around Dental Implants with Cement-Retained and Screw-Retained Restorations: A 5-Year Prospective Cohort Study in Men

Comparative Study

Comparison of Clinical, Radiographic, and Immunologic Inflammatory Parameters Around Dental Implants with Cement-Retained and Screw-Retained Restorations: A 5-Year Prospective Cohort Study in Men

Mohammad D Al Amri et al. Int J Prosthodont. 2017 Jul/Aug.

Abstract

Purpose: To compare bleeding on probing (BoP), probing depth (PD; ≥ 4 mm), radiographic (peri-implant crestal bone loss [CBL]), and immunologic inflammatory (interleukin-1beta [IL-1β] and matrix metalloproteinase-9 [MMP-9]) parameters around dental implants with cement-retained (CR) and screw-retained (SR) implant-supported crowns.

Materials and methods: Based on the mode of retention of the restoration, 51 patients were divided into two groups: Group 1, consisting of 26 single implants restored with CR crowns, and Group 2, consisting of 25 single implants restored with SR crowns. Peri-implant BoP, PD, and CBL were scored, and levels of IL-1β and MMP-9 in the peri-implant crevicular fluid (PICF) in both groups were measured in duplicate using enzyme-linked immunosorbent assay. Full-mouth mechanical debridement was performed biannually in both groups. Statistical analysis was performed using Kruskal-Wallis test with the significance level set at P < .05.

Results: The mean CBL among implants in groups 1 and 2 was 1.7 ± 0.5 mm and 1.7 ± 0.4 mm, respectively. There was no statistically significant difference in mean BoP, PD, and CBL among implants in both groups (P > .05). There was no statistically significant difference between groups 1 and 2 in the PICF levels of IL-1β (7.3 ± 0.5 and 7.2 ± 0.5, respectively) and MMP-9 (165 ± 9.4 and 182 ± 10.6, respectively) (P > .05).

Conclusion: The mode of retention of implant-supported crowns does not appear to affect their clinical correlations with BoP, PD, CBL, and levels of IL-1β and MMP-9 in the PICF when zinc oxide eugenol cement is used.

PubMed Disclaimer

Publication types

LinkOut - more resources