Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Sep;27(5):1885-1895.
doi: 10.1007/s10895-017-2127-x. Epub 2017 Jul 11.

Ultra-Sensitive Nano Optical Sensor Samarium-Doxycycline Doped in Sol Gel Matrix for Assessment of Glucose Oxidase Activity in Diabetics Disease

Affiliations

Ultra-Sensitive Nano Optical Sensor Samarium-Doxycycline Doped in Sol Gel Matrix for Assessment of Glucose Oxidase Activity in Diabetics Disease

Marwa M Tharwat et al. J Fluoresc. 2017 Sep.

Abstract

A low cost and very sensitive method for the determination of the activity of glucose oxidase enzyme in different diabetics serum samples was developed. The method based on the assessment of the H2O2 concentration produced from the reaction of the glucose oxidase (GOx) enzyme with glucose as substrate in the serum of diabetics patients by nano optical sensor Sm-doxycycline doped in sol gel matrix. H2O2 enhances the luminescence intensity of all bands of the nano Sm-doxycycline complex [Sm-(DC)2]+ doped in sol-gel matrix, especially the 645 nm band at λex = 400 nm and pH 7.0 in water. The influence of the different analytical parameters that affect the luminescence intensity of the nano optical sensor, e.g. pH, H2O2 concentration and foreign ions concentrations were studied. The remarkable enhancement of the luminescence intensity of nano optical sensor [Sm-(DC)2]+ complex in water at 645 nm by the addition of various concentrations of H2O2 was successfully used as an optical sensor for the assessment of the activity of the glucose oxidase enzyme in different diabetics serum samples. The calibration plot was achieved over the activity range 0.1-240 U/L with a correlation coefficient of 0.999 and a detection limit of 0.05 U/L.

Keywords: Enhancement; Glucose oxidase; H2O2; Luminescence intensity; Nano optical sensor; Sm-doxycycline.

PubMed Disclaimer

References

    1. Spectrochim Acta A Mol Biomol Spectrosc. 2009 Nov;74(4):972-6 - PubMed
    1. Talanta. 2013 Mar 30;107:18-24 - PubMed
    1. Anal Chem. 2010 Jul 15;82(14):6230-6 - PubMed
    1. J Fluoresc. 2005 Jul;15(4):529-42 - PubMed
    1. J Fluoresc. 2012 Mar;22(2):557-64 - PubMed

LinkOut - more resources