The feasibility of point-of-care ankle ultrasound examination in patients with recurrent ankle sprain and chronic ankle instability: Comparison with magnetic resonance imaging
- PMID: 28729007
- DOI: 10.1016/j.injury.2017.07.015
The feasibility of point-of-care ankle ultrasound examination in patients with recurrent ankle sprain and chronic ankle instability: Comparison with magnetic resonance imaging
Abstract
Objective: To evaluate the feasibility of point-of-care ankle ultrasound compared with magnetic resonance imaging (MRI) for diagnosing major ligaments and Achilles tendon injuries in patients with recurrent ankle sprain and chronic instability, and to evaluate inter-observer reliability between an emergency physician and a musculoskeletal radiology fellow.
Material and methods: A prospective cross-sectional study was conducted in an emergency department. Patients with recurrent ankle sprain and chronic instability were recruited. An emergency physician and a musculoskeletal radiology fellow independently evaluated the anterior talofibular ligament (ATFL), calcaneofibular ligament (CFL), distal anterior tibiofibular ligament (ATiFL), deltoid ligament, and Achilles tendon using point-of-care ankle ultrasound. Findings were classified normal, partial tear, and complete tear. MRI was used as the reference standard. We calculated diagnostic values for point-of-care ankle ultrasound for both reviewers and compared them using DeLong's test. Intra-class correlation coefficients (ICCs) were calculated for agreement between each reviewer and the reference standard, and between the two reviewers.
Results: Eighty-five patients were enrolled. Point-of-care ankle ultrasound showed acceptable sensitivity (96.4-100%), specificity (95.0-100%), and accuracy (96.5-100%); these performance markers did not differ significantly between reviewers. Agreement between each reviewer and the reference standard was excellent (emergency physician, ICC=0.846-1.000; musculoskeletal radiology fellow, ICC=0.930-1.000), as was inter-observer agreement (ICC=0.873-1.000).
Conclusion: Point-of-care ankle ultrasound is as precise as MRI for detecting major ankle ligament and Achilles tendon injuries; it could be used for immediate diagnosis and further pre-operative imaging. Moreover, it may reduce the interval from emergency department admission to admission for surgical intervention, and may save costs.
Keywords: Ankle instability; Ankle sprain; Emergency department; Magnetic resonance imaging; Ultrasound.