Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2017 Oct;48(10):2323-2328.
doi: 10.1016/j.injury.2017.07.015. Epub 2017 Jul 13.

The feasibility of point-of-care ankle ultrasound examination in patients with recurrent ankle sprain and chronic ankle instability: Comparison with magnetic resonance imaging

Affiliations
Comparative Study

The feasibility of point-of-care ankle ultrasound examination in patients with recurrent ankle sprain and chronic ankle instability: Comparison with magnetic resonance imaging

Sun Hwa Lee et al. Injury. 2017 Oct.

Abstract

Objective: To evaluate the feasibility of point-of-care ankle ultrasound compared with magnetic resonance imaging (MRI) for diagnosing major ligaments and Achilles tendon injuries in patients with recurrent ankle sprain and chronic instability, and to evaluate inter-observer reliability between an emergency physician and a musculoskeletal radiology fellow.

Material and methods: A prospective cross-sectional study was conducted in an emergency department. Patients with recurrent ankle sprain and chronic instability were recruited. An emergency physician and a musculoskeletal radiology fellow independently evaluated the anterior talofibular ligament (ATFL), calcaneofibular ligament (CFL), distal anterior tibiofibular ligament (ATiFL), deltoid ligament, and Achilles tendon using point-of-care ankle ultrasound. Findings were classified normal, partial tear, and complete tear. MRI was used as the reference standard. We calculated diagnostic values for point-of-care ankle ultrasound for both reviewers and compared them using DeLong's test. Intra-class correlation coefficients (ICCs) were calculated for agreement between each reviewer and the reference standard, and between the two reviewers.

Results: Eighty-five patients were enrolled. Point-of-care ankle ultrasound showed acceptable sensitivity (96.4-100%), specificity (95.0-100%), and accuracy (96.5-100%); these performance markers did not differ significantly between reviewers. Agreement between each reviewer and the reference standard was excellent (emergency physician, ICC=0.846-1.000; musculoskeletal radiology fellow, ICC=0.930-1.000), as was inter-observer agreement (ICC=0.873-1.000).

Conclusion: Point-of-care ankle ultrasound is as precise as MRI for detecting major ankle ligament and Achilles tendon injuries; it could be used for immediate diagnosis and further pre-operative imaging. Moreover, it may reduce the interval from emergency department admission to admission for surgical intervention, and may save costs.

Keywords: Ankle instability; Ankle sprain; Emergency department; Magnetic resonance imaging; Ultrasound.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources