Treatment of Mandibular Angle Fractures with Single Three-Dimensional Locking Miniplates without Maxillomandibular Fixation: How Much Fixation Is Required?
- PMID: 28751942
- PMCID: PMC5526697
- DOI: 10.1055/s-0037-1600904
Treatment of Mandibular Angle Fractures with Single Three-Dimensional Locking Miniplates without Maxillomandibular Fixation: How Much Fixation Is Required?
Abstract
The aim of this simple nonrandomized and observational study was to evaluate the efficacy of single three-dimensional (3D) plate for the treatment of mandibular angle fractures without maxillomandibular fixation. A total of 30 patients with noncomminuted fractures of mandibular angle requiring open reduction and internal fixation were included in the study. All the patients were treated by open reduction and internal fixation using single 3D titanium locking miniplate placed with the help of transbuccal trocar or Synthes 90-degree hand piece and screw driver. 3D locking titanium miniplates used in our study was four-holed, box-shaped plate, and screws with 2 mm diameter and 8 mm length. The following clinical parameters were assessed for each patient at each follow-up visit: pain (visual analog scale: 0-5), swelling (visual analog scale: 0-5), mouth opening, infection, paresthesia, hardware failure (plate fracture), occlusal discrepancies, and mobility between fracture fragments. A significant decrease in pain level was seen during the follow-up visits. No statistically significant changes were seen in swelling, but mouth opening increased in the subsequent visits. Also better results were seen in terms of fracture stability and occlusion in the postoperative period. Two cases of infection and two cases of hardware failure were noted in sixth postoperative week. 3D plating system is an easy to use alternative to conventional miniplates to treat mandibular angle fractures that uses lesser foreign material, thus reducing the operative time and overall cost of the treatment. Better fracture stability and occlusion was also achieved using the 3D plating system.
Keywords: locking plates; mandibular angle fractures; maxillomandibular fixation; three-dimensional miniplates.
Conflict of interest statement
Figures
Similar articles
-
Comparison of 3D plate and locking plate in treatment of mandibular fracture-a clinical study.Oral Maxillofac Surg. 2017 Dec;21(4):383-390. doi: 10.1007/s10006-017-0642-1. Epub 2017 Aug 7. Oral Maxillofac Surg. 2017. PMID: 28785906 Clinical Trial.
-
Comparative Evaluation of 3d Locking Versus Non-Locking Titanium Miniplates in the Treatment of Mandibular Fracture.Indian J Otolaryngol Head Neck Surg. 2020 Sep;72(3):363-369. doi: 10.1007/s12070-020-01884-z. Epub 2020 May 20. Indian J Otolaryngol Head Neck Surg. 2020. PMID: 32714854 Free PMC article.
-
Efficacy of 2-mm locking miniplates in the management of mandibular fractures without maxillomandibular fixation.Natl J Maxillofac Surg. 2011 Jan;2(1):28-32. doi: 10.4103/0975-5950.85850. Natl J Maxillofac Surg. 2011. PMID: 22442606 Free PMC article.
-
A meta-analysis comparing the 2.0-mm locking plate system with the 2.0-mm nonlocking plate system in treatment of mandible fractures.J Craniofac Surg. 2014 Nov;25(6):2094-7. doi: 10.1097/SCS.0000000000001018. J Craniofac Surg. 2014. PMID: 25304139 Review.
-
Locking Plate System Versus Standard Plate Fixation in the Management of Mandibular Fractures: Meta-Analysis of Randomized Controlled Trials.J Craniofac Surg. 2017 Sep;28(6):1456-1461. doi: 10.1097/SCS.0000000000003857. J Craniofac Surg. 2017. PMID: 28708651
Cited by
-
Prevalence of surgical site infections after open reduction and internal fixation for mandibular fractures: a systematic review and meta-analysis.Sci Rep. 2023 Jul 10;13(1):11174. doi: 10.1038/s41598-023-37652-6. Sci Rep. 2023. PMID: 37430033 Free PMC article.
-
Maxillomandibular Fixation Verses Open Reduction and Internal Fixation in Mandibular Fractures-Effect on Pulmonary Functions.J Maxillofac Oral Surg. 2024 Dec;23(6):1627-1633. doi: 10.1007/s12663-024-02327-w. Epub 2024 Sep 30. J Maxillofac Oral Surg. 2024. PMID: 39618440
-
Single linear miniplate versus rectangular grid plate in the treatment of mandibular angle fractures: A prospective, clinico-radiographic, comparative study.Natl J Maxillofac Surg. 2023 Jan-Apr;14(1):47-54. doi: 10.4103/njms.njms_129_22. Epub 2023 Apr 14. Natl J Maxillofac Surg. 2023. PMID: 37273441 Free PMC article.
-
Factors Affecting the Duration of Surgery in the Management of Condylar Head Fractures.J Clin Med. 2023 Nov 19;12(22):7172. doi: 10.3390/jcm12227172. J Clin Med. 2023. PMID: 38002784 Free PMC article.
References
-
- Schierle H P, Schmelzeisen R, Rahn B, Pytlik C. One- or two-plate fixation of mandibular angle fractures? J Craniomaxillofac Surg. 1997;25(03):162–168. - PubMed
-
- Ellis E., III Treatment methods for fractures of the mandibular angle. Int J Oral Maxillofac Surg. 1999;28(04):243–252. - PubMed
-
- Mukerji R, Mukerji G, McGurk M. Mandibular fractures: historical perspective. Br J Oral Maxillofac Surg. 2006;44(03):222–228. - PubMed
-
- Alkan A, Celebi N, Ozden B, Baş B, Inal S. Biomechanical comparison of different plating techniques in repair of mandibular angle fractures. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007;104(06):752–756. - PubMed
-
- Guimond C, Johnson J V, Marchena J M. Fixation of mandibular angle fractures with a 2.0-mm 3-dimensional curved angle strut plate. J Oral Maxillofac Surg. 2005;63(02):209–214. - PubMed
LinkOut - more resources
Full Text Sources
Other Literature Sources