. 2017 Sep;10(3):188-196.
doi: 10.1055/s-0037-1600904. Epub 2017 Mar 29.

Treatment of Mandibular Angle Fractures with Single Three-Dimensional Locking Miniplates without Maxillomandibular Fixation: How Much Fixation Is Required?

Affiliations

Treatment of Mandibular Angle Fractures with Single Three-Dimensional Locking Miniplates without Maxillomandibular Fixation: How Much Fixation Is Required?

Sanjay Rastogi et al. Craniomaxillofac Trauma Reconstr. 2017 Sep.

Abstract

The aim of this simple nonrandomized and observational study was to evaluate the efficacy of single three-dimensional (3D) plate for the treatment of mandibular angle fractures without maxillomandibular fixation. A total of 30 patients with noncomminuted fractures of mandibular angle requiring open reduction and internal fixation were included in the study. All the patients were treated by open reduction and internal fixation using single 3D titanium locking miniplate placed with the help of transbuccal trocar or Synthes 90-degree hand piece and screw driver. 3D locking titanium miniplates used in our study was four-holed, box-shaped plate, and screws with 2 mm diameter and 8 mm length. The following clinical parameters were assessed for each patient at each follow-up visit: pain (visual analog scale: 0-5), swelling (visual analog scale: 0-5), mouth opening, infection, paresthesia, hardware failure (plate fracture), occlusal discrepancies, and mobility between fracture fragments. A significant decrease in pain level was seen during the follow-up visits. No statistically significant changes were seen in swelling, but mouth opening increased in the subsequent visits. Also better results were seen in terms of fracture stability and occlusion in the postoperative period. Two cases of infection and two cases of hardware failure were noted in sixth postoperative week. 3D plating system is an easy to use alternative to conventional miniplates to treat mandibular angle fractures that uses lesser foreign material, thus reducing the operative time and overall cost of the treatment. Better fracture stability and occlusion was also achieved using the 3D plating system.

Keywords: locking plates; mandibular angle fractures; maxillomandibular fixation; three-dimensional miniplates.

PubMed Disclaimer

Conflict of interest statement

Conflict of Interest None.

Figures

Fig. 1
Fig. 1
Right mandibular angle fracture with left parasymphysis fracture.
Fig. 2
Fig. 2
3D locking miniplate used for fixation of right mandibular angle and left parasymphysis fracture.

Similar articles

Cited by

References

    1. Schierle H P, Schmelzeisen R, Rahn B, Pytlik C. One- or two-plate fixation of mandibular angle fractures? J Craniomaxillofac Surg. 1997;25(03):162–168. - PubMed
    1. Ellis E., III Treatment methods for fractures of the mandibular angle. Int J Oral Maxillofac Surg. 1999;28(04):243–252. - PubMed
    1. Mukerji R, Mukerji G, McGurk M. Mandibular fractures: historical perspective. Br J Oral Maxillofac Surg. 2006;44(03):222–228. - PubMed
    1. Alkan A, Celebi N, Ozden B, Baş B, Inal S. Biomechanical comparison of different plating techniques in repair of mandibular angle fractures. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007;104(06):752–756. - PubMed
    1. Guimond C, Johnson J V, Marchena J M. Fixation of mandibular angle fractures with a 2.0-mm 3-dimensional curved angle strut plate. J Oral Maxillofac Surg. 2005;63(02):209–214. - PubMed