Detailed Investigation and Comparison of the XCMS and MZmine 2 Chromatogram Construction and Chromatographic Peak Detection Methods for Preprocessing Mass Spectrometry Metabolomics Data
- PMID: 28752757
- DOI: 10.1021/acs.analchem.7b01069
Detailed Investigation and Comparison of the XCMS and MZmine 2 Chromatogram Construction and Chromatographic Peak Detection Methods for Preprocessing Mass Spectrometry Metabolomics Data
Abstract
XCMS and MZmine 2 are two widely used software packages for preprocessing untargeted LC/MS metabolomics data. Both construct extracted ion chromatograms (EICs) and detect peaks from the EICs, the first two steps in the data preprocessing workflow. While both packages have performed admirably in peak picking, they also detect a problematic number of false positive EIC peaks and can also fail to detect real EIC peaks. The former and latter translate downstream into spurious and missing compounds and present significant limitations with most existing software packages that preprocess untargeted mass spectrometry metabolomics data. We seek to understand the specific reasons why XCMS and MZmine 2 find the false positive EIC peaks that they do and in what ways they fail to detect real compounds. We investigate differences of EIC construction methods in XCMS and MZmine 2 and find several problems in the XCMS centWave peak detection algorithm which we show are partly responsible for the false positive and false negative compound identifications. In addition, we find a problem with MZmine 2's use of centWave. We hope that a detailed understanding of the XCMS and MZmine 2 algorithms will allow users to work with them more effectively and will also help with future algorithmic development.
Similar articles
-
One Step Forward for Reducing False Positive and False Negative Compound Identifications from Mass Spectrometry Metabolomics Data: New Algorithms for Constructing Extracted Ion Chromatograms and Detecting Chromatographic Peaks.Anal Chem. 2017 Sep 5;89(17):8696-8703. doi: 10.1021/acs.analchem.7b00947. Epub 2017 Aug 17. Anal Chem. 2017. PMID: 28752754
-
Comparative evaluation of preprocessing freeware on chromatography/mass spectrometry data for signature discovery.J Chromatogr A. 2014 Sep 5;1358:155-64. doi: 10.1016/j.chroma.2014.06.100. Epub 2014 Jul 7. J Chromatogr A. 2014. PMID: 25063004
-
Metabolomics Data Preprocessing Using ADAP and MZmine 2.Methods Mol Biol. 2020;2104:25-48. doi: 10.1007/978-1-0716-0239-3_3. Methods Mol Biol. 2020. PMID: 31953811 Free PMC article.
-
[A review and research prospects on the application of the XCMS mass-spectrometry data-processing software in the environmental science field].Se Pu. 2025 Jun;43(6):585-593. doi: 10.3724/SP.J.1123.2025.01019. Se Pu. 2025. PMID: 40394738 Free PMC article. Review. Chinese.
-
A roadmap for the XCMS family of software solutions in metabolomics.Curr Opin Chem Biol. 2016 Feb;30:87-93. doi: 10.1016/j.cbpa.2015.11.009. Epub 2015 Dec 11. Curr Opin Chem Biol. 2016. PMID: 26673825 Free PMC article. Review.
Cited by
-
A Metabolomics Workflow for Analyzing Complex Biological Samples Using a Combined Method of Untargeted and Target-List Based Approaches.Metabolites. 2020 Aug 25;10(9):342. doi: 10.3390/metabo10090342. Metabolites. 2020. PMID: 32854199 Free PMC article.
-
Integrative omics approaches provide biological and clinical insights: examples from mitochondrial diseases.J Clin Invest. 2020 Jan 2;130(1):20-28. doi: 10.1172/JCI129202. J Clin Invest. 2020. PMID: 31895050 Free PMC article. Review.
-
JPA: Joint Metabolic Feature Extraction Increases the Depth of Chemical Coverage for LC-MS-Based Metabolomics and Exposomics.Metabolites. 2022 Feb 26;12(3):212. doi: 10.3390/metabo12030212. Metabolites. 2022. PMID: 35323655 Free PMC article.
-
From Centroided to Profile Mode: Machine Learning for Prediction of Peak Width in HRMS Data.Anal Chem. 2021 Dec 14;93(49):16562-16570. doi: 10.1021/acs.analchem.1c03755. Epub 2021 Nov 29. Anal Chem. 2021. PMID: 34843646 Free PMC article.
-
Metabolic Implications of Using BioOrthogonal Non-Canonical Amino Acid Tagging (BONCAT) for Tracking Protein Synthesis.Front Microbiol. 2020 Feb 13;11:197. doi: 10.3389/fmicb.2020.00197. eCollection 2020. Front Microbiol. 2020. PMID: 32117186 Free PMC article.