Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2018 Jan;15(1):99-106.
doi: 10.1016/j.hrthm.2017.07.034. Epub 2017 Jul 29.

Circadian variability patterns predict and guide premature ventricular contraction ablation procedural inducibility and outcomes

Affiliations
Multicenter Study

Circadian variability patterns predict and guide premature ventricular contraction ablation procedural inducibility and outcomes

David Hamon et al. Heart Rhythm. 2018 Jan.

Abstract

Background: Infrequent intraprocedural premature ventricular complexes (PVCs) may impede radiofrequency catheter ablation (RFA) outcome, and pharmacologic induction is unpredictable.

Objective: The purpose of this study was to determine whether PVC circadian variation could help predict drug response.

Methods: Consecutive patients referred for RFA with detailed Holter monitoring and frequent monomorphic PVCs were included. Patients were divided into 3 groups based on hourly PVC count relationship to corresponding mean heart rate (HR) during each of the 24 hours on Holter: fast-HR-dependent PVC (F-HR-PVC) type for a positive correlation (Pearson, P <.05), slow-HR-dependent PVC (S-HR-PVC) type for a negative correlation, and independent-HR-PVC (I-HR-PVC) when no correlation was found.

Results: Fifty-one of the 101 patients (50.5%) had F-HR-PVC, 39.6% I-HR-PVC, and 9.9% S-HR-PVC; 30.7% had infrequent intraprocedural PVC requiring drug infusion. The best predictor of infrequent PVC was number of hours with PVC count <120/h on Holter (area under the curve 0.80, sensitivity 83.9%, specificity 74.3%, for ≥2 h). Only F-HR-PVC patients responded to isoproterenol. Isoproterenol washout or phenylephrine infusion was successful for the 3 S-HR-PVC patients, and no drug could increase PVC frequency in the 12 I-HR-PVC patients. Long-term RFA success rate in patients with frequent PVCs at baseline (82.9%) was similar to those with infrequent PVC who responded to a drug (77.8%; P = .732) but significantly higher than for those who did not respond to any drug (15.4%; P <.0001).

Conclusion: A simple analysis of Holter PVC circadian variability provides incremental value to guide pharmacologic induction of PVCs during RFA and predict outcome. Patients with infrequent I-HR-PVC had the least successful outcomes from RF ablation.

Keywords: Autonomic nervous system; Circadian profile; Isoproterenol; Premature ventricular complexes; Radiofrequency ablation.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources