In vivo interference of Ioversol in serum and urine capillary electrophoresis: an optimized protocol for sample collection
- PMID: 28771431
- DOI: 10.1515/cclm-2017-0509
In vivo interference of Ioversol in serum and urine capillary electrophoresis: an optimized protocol for sample collection
Keywords: Ioversol; capillary electrophoresis; interference; iodinated contrast.
Similar articles
-
[Detecting a peak in fraction beta by capillary electrophoresis: interference due to iomeprol].Ann Biol Clin (Paris). 2013 Mar-Apr;71(2):196-8. doi: 10.1684/abc.2013.0799. Ann Biol Clin (Paris). 2013. PMID: 23587586 French.
-
Stereoisomerism in contrast media. Ioversol.Invest Radiol. 1990 Sep;25 Suppl 1:S102-3. doi: 10.1097/00004424-199009001-00047. Invest Radiol. 1990. PMID: 2283217 No abstract available.
-
Interferences in clinical capillary zone electrophoresis of serum proteins.Electrophoresis. 2004 Jun;25(10-11):1485-7. doi: 10.1002/elps.200305820. Electrophoresis. 2004. PMID: 15188230 Review.
-
It's just an illusion.Clin Chem. 2014 Oct;60(10):1351-2. doi: 10.1373/clinchem.2013.220921. Clin Chem. 2014. PMID: 25267517 No abstract available.
-
Peaks and tails: Evaluation of irregularities in capillary serum protein electrophoresis.Clin Biochem. 2018 Jan;51:48-55. doi: 10.1016/j.clinbiochem.2017.09.017. Epub 2017 Sep 28. Clin Biochem. 2018. PMID: 28965683 Review.
Cited by
-
Analytical interference of intravascular contrast agents with clinical laboratory tests: a joint guideline by the ESUR Contrast Media Safety Committee and the Preanalytical Phase Working Group of the EFLM Science Committee.Eur Radiol. 2024 Jul;34(7):4821-4827. doi: 10.1007/s00330-023-10411-x. Epub 2023 Dec 7. Eur Radiol. 2024. PMID: 38060004 Free PMC article. Review.
-
Detection of monoclonal protein by capillary zone electrophoresis can be challenged by iodinated contrast agent interference: a case report.Biochem Med (Zagreb). 2021 Jun 15;31(2):021001. doi: 10.11613/BM.2021.021001. Epub 2021 Apr 15. Biochem Med (Zagreb). 2021. PMID: 33927559 Free PMC article.
References
-
- Cornes MP. Exogenous sample contamination. Sources and interference. Clin Biochem 2016;49:1340–5.
-
- Bossuyt X. Separation of serum proteins by automated capillary zone electrophoresis. Clin Chem Lab Med 2003;41:762–72.
-
- Gay-Bellile C, Bengoufa D, Houze P, Le Carrer D, Benlakehal M, Bousquet B, et al. Automated multicapillary electrophoresis for analysis of human serum proteins. Clin Chem 2003;49:1909–15.
-
- Arranz-Peña ML, González-Sagrado M, Olmos-Linares AM, Fernández-García N, Martin-Gil FJ. Interference of iodinated contrast media in serum capillary zone electrophoresis. Clin Chem 2000;46:736–7.
-
- Larsson A, Lindqvist A, Hillered L. Pseudoparaproteinemia detected by CE due to Omnipaque™ Infusion: a case report. Chromatographia 2007;65:775–7.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources