The standardized EEG electrode array of the IFCN
- PMID: 28778476
- DOI: 10.1016/j.clinph.2017.06.254
The standardized EEG electrode array of the IFCN
Abstract
Standardized EEG electrode positions are essential for both clinical applications and research. The aim of this guideline is to update and expand the unifying nomenclature and standardized positioning for EEG scalp electrodes. Electrode positions were based on 20% and 10% of standardized measurements from anatomical landmarks on the skull. However, standard recordings do not cover the anterior and basal temporal lobes, which is the most frequent source of epileptogenic activity. Here, we propose a basic array of 25 electrodes including the inferior temporal chain, which should be used for all standard clinical recordings. The nomenclature in the basic array is consistent with the 10-10-system. High-density scalp EEG arrays (64-256 electrodes) allow source imaging with even sub-lobar precision. This supplementary exam should be requested whenever necessary, e.g. search for epileptogenic activity in negative standard EEG or for presurgical evaluation. In the near future, nomenclature for high density electrodes arrays beyond the 10-10 system needs to be defined, to allow comparison and standardized recordings across centers. Contrary to the established belief that smaller heads needs less electrodes, in young children at least as many electrodes as in adults should be applied due to smaller skull thickness and the risk of spatial aliasing.
Keywords: 10–10-system; 10–5-system; Electrodes; High density EEG; Montage; Routine EEG; Scalp; Standard EEG; Temporal.
Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.
Comment in
-
New recommendations of the IFCN: From scalp EEG to electrical brain imaging.Clin Neurophysiol. 2017 Oct;128(10):2068-2069. doi: 10.1016/j.clinph.2017.07.413. Epub 2017 Aug 5. Clin Neurophysiol. 2017. PMID: 28826818 No abstract available.
-
Reply to "10-10 electrode system for EEG recording".Clin Neurophysiol. 2018 May;129(5):1104. doi: 10.1016/j.clinph.2018.01.064. Epub 2018 Feb 10. Clin Neurophysiol. 2018. PMID: 29472135 No abstract available.
-
10-10 electrode system for EEG recording.Clin Neurophysiol. 2018 May;129(5):1103. doi: 10.1016/j.clinph.2018.01.065. Epub 2018 Feb 11. Clin Neurophysiol. 2018. PMID: 29496396 No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical