Review
. 2017 Nov:83:153-160.
doi: 10.1016/j.archoralbio.2017.07.022. Epub 2017 Jul 29.

Influences of microgap and micromotion of implant-abutment interface on marginal bone loss around implant neck

Affiliations
Review

Influences of microgap and micromotion of implant-abutment interface on marginal bone loss around implant neck

Yang Liu et al. Arch Oral Biol. 2017 Nov.

Abstract

Objective: To review the influences and clinical implications of micro-gap and micro-motion of implant-abutment interface on marginal bone loss around the neck of implant.

Design: Literatures were searched based on the following Keywords: implant-abutment interface/implant-abutment connection/implant-abutment conjunction, microgap, micromotion/micromovement, microleakage, and current control methods available. The papers were then screened through titles, abstracts, and full texts.

Results: A total of 83 studies were included in the literature review. Two-piece implant systems are widely used in clinics. However, the production error and masticatory load result in the presence of microgap and micromotion between the implant and the abutment, which directly or indirectly causes microleakage and mechanical damage. Consequently, the degrees of microgap and micromotion further increase, and marginal bone absorption finally occurs. We summarize the influences of microgap and micromotion at the implant-abutment interface on marginal bone loss around the neck of the implant. We also recommend some feasible methods to reduce their effect.

Conclusions: Clinicians and patients should pay more attention to the mechanisms as well as the control methods of microgap and micromotion. To reduce the corresponding detriment to the implant marginal bone, suitable Morse taper or hybrid connection implants and platform switching abutments should be selected, as well as other potential methods.

Keywords: Implant-abutment interface; Marginal bone loss; Microgap; Microleakage; Micromotion.