Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Mar;36(3):847-853.
doi: 10.1002/jor.23676. Epub 2017 Aug 29.

In situ force in the anterior cruciate ligament, the lateral collateral ligament, and the anterolateral capsule complex during a simulated pivot shift test

Affiliations
Free article

In situ force in the anterior cruciate ligament, the lateral collateral ligament, and the anterolateral capsule complex during a simulated pivot shift test

Kevin M Bell et al. J Orthop Res. 2018 Mar.
Free article

Abstract

The role of the anterolateral capsule complex in knee rotatory stability remains controversial. Therefore, the objective of this study was to determine the in situ forces in the anterior cruciate ligament (ACL), the anterolateral capsule, the lateral collateral ligament (LCL), and the forces transmitted between each region of the anterolateral capsule in response to a simulated pivot shift test. A robotic testing system applied a simulated pivot shift test continuously from full extension to 90° of flexion to intact cadaveric knees (n = 7). To determine the magnitude of the in situ forces, kinematics of the intact knee were replayed in position control mode after the following procedures were performed: (i) ACL transection; (ii) capsule separation; (iii) anterolateral capsule transection; and (iii) LCL transection. A repeated measures ANOVA was performed to compare in situ forces between each knee state (*p < 0.05). The in situ force in the ACL was significantly greater than the forces transmitted between each region of the anterolateral capsule at 5° and 15° of flexion but significantly lower at 60°, 75°, and 90° of flexion. This study demonstrated that the ACL is the primary rotatory stabilizer at low flexion angles during a simulated pivot shift test in the intact knee, but the anterolateral capsule plays an important secondary role at flexion angles greater than 60°. Furthermore, the contribution of the "anterolateral ligament" to rotatory knee stability in this study was negligible during a simulated pivot shift test. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:847-853, 2018.

Keywords: ACL; anterior cruciate ligament; anterolateral capsule; robotic testing system; simulated pivot shift.

PubMed Disclaimer

Publication types

LinkOut - more resources