Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Aug 10;17(1):140.
doi: 10.1186/s12886-017-0535-y.

Changes in macular sensitivity after half-dose photodynamic therapy for chronic central serous chorioretinopathy

Affiliations

Changes in macular sensitivity after half-dose photodynamic therapy for chronic central serous chorioretinopathy

Alp Atik et al. BMC Ophthalmol. .

Abstract

Background: To evaluate the macular sensitivity changes after half-dose photodynamic therapy (PDT) for chronic central serous chorioretinopathy (CSCR).

Methods: Eighteen patients (26 eyes) with chronic CSCR were recruited in the same hospital between April 2011 and December 2012. All patients were treated with one session of half-dose PDT after complete ophthalmic examination. Macular sensitivity examination was performed at baseline and 1, 3 and 6 months post-treatment. Mean sensitivity (MS) of the central 10 degrees (10°) and 4 degrees (4°), mean deviation (MD) and pattern standard deviation (PSD) on automated static perimetry (Humphrey Field Analyzer II-750) were used for analysis.

Results: There was significant improvement of the 10°MS from baseline (29.76 ± 1.51 dB) to 1 month (31.74 ± 1.56 dB), 3 months (31.51 ± 1.38 dB) and 6 months (31.19 ± 1.61 dB) after treatment (P < 0.001). The 4°MS was also significantly improved with half-dose PDT from baseline (28.96 ± 1.78 dB) to 1 month (32.41 ± 1.66 dB), 3 months (32.46 ± 1.50 dB) and 6 months (31.90 ± 1.84 dB) post-treatment (P < 0.001). MD was improved from baseline (-3.39 ± 0.89 dB) to 1 month (-1.96 ± 0.29 dB), 3 months (-1.94 ± 0.29 dB) and 6 months (-2.45 ± 0.13) post-treatment (P = 0.004). PSD also improved from 1.97 ± 0.24 dB at baseline to 1.47 ± 0.27 dB, 1.34 ± 0.24 dB, and 1.53 ± 0.24 dB (P = 0.001) at 1, 3 and 6 months after treatment, respectively.

Conclusion: Macular sensitivity in CSCR can be improved by half-dose PDT, along with improvement of visual acuity and retinal thickness. The treatment outcome at 1 month may be a predictor of the final treatment response.

Keywords: Automated static perimetry; Central serous chorioretinopathy (CSCR); Macular sensitivity; Photodynamic therapy (PDT); Visual field.

PubMed Disclaimer

Conflict of interest statement

Ethics approval and consent to participate

This prospective study was in agreement with the Declaration of Helsinki and approved by the Institutional Review Board of the First Affiliated Hospital of Kunming Medical University. Informed consent was obtained from each patient.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Similar articles

Cited by

References

    1. Nicholson B, Noble J, Forooghian F, Meyerle C. Central serous chorioretinopathy: update on pathophysiology and treatment. Surv Ophthalmol. 2013;58(2):103–126. doi: 10.1016/j.survophthal.2012.07.004. - DOI - PMC - PubMed
    1. Loo RH, Scott IU, Flynn HW, Jr, Gass JD, Murray TG, Lewis ML, Rosenfeld PJ, Smiddy WE. Factors associated with reduced visual acuity during long-term follow-up of patients with idiopathic central serous chorioretinopathy. Retina. 2002;22(1):19–24. doi: 10.1097/00006982-200202000-00004. - DOI - PubMed
    1. Baran NV, Gurlu VP, Esgin H. Long-term macular function in eyes with central serous chorioretinopathy. Clin Experiment Ophthalmol. 2005;33(4):369–372. doi: 10.1111/j.1442-9071.2005.01027.x. - DOI - PubMed
    1. Folk JC, Thompson HS, Han DP, Brown CK. Visual function abnormalities in central serous retinopathy. Arch Ophthalmol. 1984;102(9):1299–1302. doi: 10.1001/archopht.1984.01040031049021. - DOI - PubMed
    1. Maaranen TH, Tuppurainen KT, Mantyjarvi MI. Color vision defects after central serous chorioretinopathy. Retina. 2000;20(6):633–637. doi: 10.1097/00006982-200011000-00008. - DOI - PubMed

LinkOut - more resources