Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Mar;21(3):291-295.
doi: 10.1016/j.jsams.2017.07.022. Epub 2017 Jul 31.

Validity of the ActiGraph GT3X+ and BodyMedia SenseWear Armband to estimate energy expenditure during physical activity and sport

Affiliations

Validity of the ActiGraph GT3X+ and BodyMedia SenseWear Armband to estimate energy expenditure during physical activity and sport

Paul B Gastin et al. J Sci Med Sport. 2018 Mar.

Abstract

Objectives: The purpose of this study was to assess the validity of the ActiGraph GT3X+ (GT3X+) and the BodyMedia SenseWear Armband (SWA) to estimate energy expenditure (EE) during physical activity and field sport movements.

Design: Criterion validity.

Methods: Twenty-six active adults completed a single 90min session involving alternating intervals of exercise (5min) and recovery (10min). Exercise involved walking (4km/h), jogging (8km/h), running (12km/h) or a sport-simulated circuit (three intervals). Participants wore two triaxial accelerometers (GT3X+ and SWA) and a portable gas analyser (MetaMax 3B), used as the criterion measure.

Results: Total EE was significantly underestimated (p<0.01) by the GT3X+ (mean bias±SD: -374.5±132.84kJ; % difference=-29.3%) and SWA (-244.3±148.0kJ; -18.2%). Overestimations were made by both accelerometers during the walk (GT3X+: 27.4±30.8kJ; SWA: 32.1±15.4kJ) and jog (38.0±30.0kJ; 34.5±31.6kJ). Underestimations were evident during the run (-41.2±25.1kJ; -43.8±33.5kJ) and circuit (C1: GTX+: -127.2±41.6kJ; SWA: -86.1±40.2kJ). Error of estimation increased in magnitude as the intensity of exercise increased (GT3X+: 40.8-143.0kJ; SWA: 35.5-102.0kJ).

Conclusions: The ActiGraph GT3X+ and BodyMedia SWA do not provide valid EE estimates across a range of exercise modalities and intensities when compared to a criterion measure. Poor accuracy and large precision errors, particularly during high intensity and intermittent movement patterns, suggest these devices have limitations and should be used cautiously in the field.

Keywords: Accelerometer; Excess post-exercise oxygen consumption; High intensity intermittent exercise; Locomotion; Recovery; Team sports.

PubMed Disclaimer

Similar articles

Cited by

Publication types