Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2017 Sep;72(9):1097-1106.
doi: 10.1111/anae.13984.

A randomised trial comparing real-time double-lumen endobronchial tube placement with the Disposcope® with conventional blind placement

Affiliations
Free article
Randomized Controlled Trial

A randomised trial comparing real-time double-lumen endobronchial tube placement with the Disposcope® with conventional blind placement

P T Chen et al. Anaesthesia. 2017 Sep.
Free article

Abstract

Double-lumen endobronchial tube placement is challenging. This study compared double-lumen tube placement with the Disposcope® , a wireless videostylet allowing real-time visualisation, with conventional blind placement. Patients undergoing elective thoracic surgery with normal airways requiring one-lung ventilation were randomly allocated into two groups (27 patients in each group). The Disposcope was used to assist left-sided double-lumen tube placement in one group, and conventional blind placement was performed in the control group. Placement in both groups was checked with fibreoptic bronchoscopy. The Disposcope-assisted group had a shorter total mean (SD) placement time (18.6 (2.5) s vs. 21.4 (2.9) s, p < 0.001), laryngoscopy to end of auscultation time (83.4 (3.0) s vs. 93.9 (5.7) s, p < 0.001) and total operation time (130.7 (6.1) s vs. 154.5 (6.3) s, p < 0.001). In the Disposcope-assisted group, the double-lumen tube was inserted in the correct side in all patients (100.0%), whereas in the conventional group, the double-lumen tube was placed in the correct side in 25 (92.6%) patients and in the wrong side in 2 (7.4%) patients; the difference was not significant (p = 0.150). In the Disposcope-assisted group, the double-lumen tube was inserted to the optimal depth in 24 (88.9%) patients, whereas in the conventional group it was inserted to the optimal depth in one (4.0%) patient. The Disposcope increased the success rate of double-lumen tube placement, and shortened the total operation time when compared with standard placement with confirmation using fibreoptic bronchoscopy, and may replace the conventional method.

Keywords: chest surgery; double-lumen endobronchial tube; fibreoptic; videostylet.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources