Airway calibre variation is a major determinant of exhaled nitric oxide's ability to capture asthma control

Affiliations
Free article

Airway calibre variation is a major determinant of exhaled nitric oxide's ability to capture asthma control

Alain Michils et al. Eur Respir J. .
Free article

Abstract

Changes in airway calibre have the potential to modify exhaled nitric oxide fraction (FENO) values and could hamper how FENO captures changes in asthma control. Here, our objective was to assess whether forced expiratory volume in 1 s (FEV1) variations alter the ability of FENO to reflect asthma control.FENO, asthma control (Asthma Control Questionnaire (ACQ)) and FEV1 were measured at least two times in 527 patients during 1819 pairs of visits. Determinants of FENO-ACQ discordance probability were evaluated through a logistic regression analysis. The effectiveness of FENO at capturing either asthma control worsening or improvement between two visits was then assessed by undertaking a stratified receiver operating characteristic curves analysis.When FEV1 and FENO change in the same direction, the odds of FENO-ACQ being discordant are multiplied by 3 (p<0.001). The area under the curve values were 0.765 (95% CI 0.713-0.805) (improvement; p<0.001) and 0.769 (95% 0.706-0.810) (worsening; p<0.001) or 0.590 (95% 0.531-0.653) (improvement; p=0.001) and 0.498 (95% 0.416-0.567) (worsening; p=0.482) when FEV1 and FENO changed in the opposite or same direction, respectively.The manner in which FENO and FEV1 vary concomitantly when asthma control changes determines the ability of FENO to capture this change: parallel or opposite changes in FEV1 and FENO either decrease or increase this ability to capture asthma control changes.

PubMed Disclaimer

Conflict of interest statement

Conflict of interest: Disclosures can be found alongside this article at erj.ersjournals.com

References

    1. Front Physiol. 2016 Jun 28;7:255 - PubMed
    1. Clin Exp Allergy. 2009 Apr;39(4):478-90 - PubMed
    1. Eur Respir J. 2014 Feb;43(2):343-73 - PubMed
    1. Allergy Asthma Proc. 2008 Mar-Apr;29(2):171-6 - PubMed
    1. Clin Exp Allergy. 2005 Sep;35(9):1175-9 - PubMed

Publication types

LinkOut - more resources