Cephalomedullary Nail Fixation of Intertrochanteric Femur Fractures: Are Two Proximal Screws Better Than One?
- PMID: 28827501
- DOI: 10.1097/BOT.0000000000000967
Cephalomedullary Nail Fixation of Intertrochanteric Femur Fractures: Are Two Proximal Screws Better Than One?
Erratum in
-
Cephalomedullary Nail Fixation of Intertrochanteric Femur Fractures: Are Two Proximal Screws Better Than One?: Erratum.J Orthop Trauma. 2018 Feb;32(2):e75. doi: 10.1097/BOT.0000000000001098. J Orthop Trauma. 2018. PMID: 29373380 No abstract available.
Abstract
Objectives: To analyze radiographic changes in intertrochanteric (IT) fracture alignment after treatment with either a single sliding lag screw or an integrated compressed and locked, dual screw, cephalomedullary nail construct.
Design: Retrospective comparative study.
Setting: Level 1 regional trauma center.
Patients: 1004 OTA/AO 31A, 31B2.1 fractures treated with either a single screw cephalomedullary nail (Gamma 3) or an integrated dual screw cephalomedullary nail (InterTAN) between February 1, 2005, and June 30, 2013. Four hundred thirteen remained after exclusion criteria; 130 were treated with a single screw device (79 stable and 51 unstable), and 283 with an integrated dual screw device (155 stable and 128 unstable).
Intervention: Cephalomedullary nail insertion.
Outcome measures: Radiographic analysis included fracture pattern, fracture reduction, neck-shaft angle (NSA), and femoral neck shortening (FNS) differences at 3, 6, and 12 months. Measurements were normalized using known lag screw dimensions, digitally corrected for magnification. Rotation between x-rays was controlled using a ratio of known to measured dimensions. The Mann-Whitney U test was used for statistical analysis.
Results: The single screw device resulted in 2.5 times more varus collapse (NSA) and 2 times more FNS over 1 year, as compared to the locked, integrated dual screw device, regardless of stability (P < 0.001). NSA and FNS changes were greater for both devices in unstable fracture patterns, but significantly less movement occurred with the dual screw device (P < 0.001).
Conclusions: A cephalomedullary nail with 2 integrated proximal screws that can be compressed and then locked seems to maintain initial IT fracture reduction and subsequent position over time, with less varus collapse and less shortening than a single screw device.
Level of evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials