Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2017 Aug 28;10(16):1633-1642.
doi: 10.1016/j.jcin.2017.05.033.

Safety and Efficacy of Polymer-Free Biolimus A9-Coated Versus Bare-Metal Stents in Orally Anticoagulated Patients: 2-Year Results of the LEADERS FREE Oral Anticoagulation Substudy

Affiliations
Free article
Randomized Controlled Trial

Safety and Efficacy of Polymer-Free Biolimus A9-Coated Versus Bare-Metal Stents in Orally Anticoagulated Patients: 2-Year Results of the LEADERS FREE Oral Anticoagulation Substudy

Didier Carrié et al. JACC Cardiovasc Interv. .
Free article

Abstract

Objectives: The aim of this study was to compare the performance of drug-coated stents (DCS) versus bare-metal stents (BMS) in patients who are candidates for long-term oral anticoagulation (OAC) after percutaneous coronary interventions.

Background: The randomized controlled LEADERS FREE (A Randomized Clinical Evaluation of the BioFreedom™ Stent) trial demonstrated the superior safety and efficacy of a polymer-free biolimus A9 DCS compared with a similar BMS used with 1 month of dual antiplatelet therapy in 2,466 patients at high bleeding risk.

Methods: The 2 stents were compared in a pre-specified analysis of the 879 LEADERS FREE patients (35.6%) scheduled to remain on OAC after percutaneous coronary intervention. The primary safety endpoint was a composite of cardiac death, myocardial infarction, and stent thrombosis. The primary efficacy endpoint was the incidence of clinically driven target lesion revascularization.

Results: Baseline characteristics of 448 DCS and 431 BMS recipients were similar, 78.8% had histories of atrial fibrillation, and 21% presented with acute coronary syndromes. Four hundred patients in the DCS group and 376 in the BMS group were discharged on OAC after percutaneous coronary intervention. At 2 years, for the DCS and BMS recipients, respectively, the incidence of clinically driven target lesion revascularization was 7.5% versus 11.2% (hazard ratio: 0.63; 95% confidence interval: 0.40 to 1.01; p = 0.0514), the safety endpoint was reached by 14.4% and 15.0% (p = NS), and the rates of major bleeding events (Bleeding Academic Research Consortium 3 to 5) were 10.7% and 12.9% (p = NS).

Conclusions: The efficacy advantage of DCS over BMS up to 2 years appears confirmed in patients on long-term OAC. Despite the very short course of dual antiplatelet therapy, both the DCS and BMS groups experienced similarly high rates of major bleeding. (A Randomized Clinical Evaluation of the BioFreedom™ Stent [Leaders Free]; NCT01623180).

Keywords: antiplatelet therapy; antithrombotic therapy; bare-metal coronary stent(s); bleeding; chronic anticoagulation; drug-coated coronary stent(s); percutaneous coronary intervention.

PubMed Disclaimer

Comment in

Publication types

MeSH terms

Associated data