Catheter Ablation Versus Medical Rate Control in Atrial Fibrillation and Systolic Dysfunction: The CAMERA-MRI Study
- PMID: 28855115
- DOI: 10.1016/j.jacc.2017.08.041
Catheter Ablation Versus Medical Rate Control in Atrial Fibrillation and Systolic Dysfunction: The CAMERA-MRI Study
Abstract
Background: Atrial fibrillation (AF) and left ventricular systolic dysfunction (LVSD) frequently co-exist despite adequate rate control. Existing randomized studies of AF and LVSD of varying etiologies have reported modest benefits with a rhythm control strategy.
Objectives: The goal of this study was to determine whether catheter ablation (CA) for AF could improve LVSD compared with medical rate control (MRC) where the etiology of the LVSD was unexplained, apart from the presence of AF.
Methods: This multicenter, randomized clinical trial enrolled patients with persistent AF and idiopathic cardiomyopathy (left ventricular ejection fraction [LVEF] ≤45%). After optimization of rate control, patients underwent cardiac magnetic resonance (CMR) to assess LVEF and late gadolinium enhancement, indicative of ventricular fibrosis, before randomization to either CA or ongoing MRC. CA included pulmonary vein isolation and posterior wall isolation. AF burden post-CA was assessed by using an implanted loop recorder, and adequacy of MRC was assessed by using serial Holter monitoring. The primary endpoint was change in LVEF on repeat CMR at 6 months.
Results: A total of 301 patients were screened; 68 patients were enrolled between November 2013 and October 2016 and randomized with 33 in each arm (accounting for 2 dropouts). The average AF burden post-CA was 1.6 ± 5.0% at 6 months. In the intention-to-treat analysis, absolute LVEF improved by 18 ± 13% in the CA group compared with 4.4 ± 13% in the MRC group (p < 0.0001) and normalized (LVEF ≥50%) in 58% versus 9% (p = 0.0002). In those undergoing CA, the absence of late gadolinium enhancement predicted greater improvements in absolute LVEF (10.7%; p = 0.0069) and normalization at 6 months (73% vs. 29%; p = 0.0093).
Conclusions: AF is an underappreciated reversible cause of LVSD in this population despite adequate rate control. The restoration of sinus rhythm with CA results in significant improvements in ventricular function, particularly in the absence of ventricular fibrosis on CMR. This outcome challenges the current treatment paradigm that rate control is the appropriate strategy in patients with AF and LVSD. (Catheter Ablation Versus Medical Rate Control in Atrial Fibrillation and Systolic Dysfunction [CAMERA-MRI]; ACTRN12613000880741).
Keywords: catheter ablation; idiopathic cardiomyopathy; late gadolinium enhancement; medical rate control; persistent AF.
Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Comment in
-
Catheter Ablation for Rate-Controlled Atrial Fibrillation: New Horizon in Heart Failure Treatment.J Am Coll Cardiol. 2017 Oct 17;70(16):1962-1963. doi: 10.1016/j.jacc.2017.08.040. Epub 2017 Aug 27. J Am Coll Cardiol. 2017. PMID: 28855116 Free PMC article. No abstract available.
-
Beyond Pulmonary Vein Isolation During Catheter Ablation in Atrial Fibrillation and Systolic Dysfunction.J Am Coll Cardiol. 2018 Mar 20;71(11):1292-1293. doi: 10.1016/j.jacc.2017.11.074. J Am Coll Cardiol. 2018. PMID: 29544616 No abstract available.
-
Reply: Beyond Pulmonary Vein Isolation During Catheter Ablation in Atrial Fibrillation and Systolic Dysfunction.J Am Coll Cardiol. 2018 Mar 20;71(11):1293-1294. doi: 10.1016/j.jacc.2018.01.019. J Am Coll Cardiol. 2018. PMID: 29544617 No abstract available.
-
Who benefit most from catheter ablation of persistent atrial fibrillation?J Thorac Dis. 2018 Feb;10(2):614-616. doi: 10.21037/jtd.2018.01.12. J Thorac Dis. 2018. PMID: 29607122 Free PMC article. No abstract available.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical