Effect of Optic Nerve Disinsertion During Evisceration on Nonporous Implant Migration: A Comparative Case Series and a Review of Literature
- PMID: 28863119
- DOI: 10.1097/IOP.0000000000000987
Effect of Optic Nerve Disinsertion During Evisceration on Nonporous Implant Migration: A Comparative Case Series and a Review of Literature
Abstract
Aim: To determine whether evisceration with optic nerve disinsertion and nonporous implant placement increases the risk of implant migration.
Methods: This was a single-center, retrospective consecutive comparative interventional case series including patients undergoing evisceration with nonporous implant between January and December 2014. Patients were grouped into 2 groups: group I where the optic nerve was not disinserted (n = 37) and group II with optic nerve disinsertion (n = 50). Implant migration was assessed clinically and on patient photographs. Migration was subclassified as decentration that did not affect the prosthetic outcome and displacement that affected the prosthetic outcome. The secondary outcome measures were the mean implant diameter, volume of the custom ocular prosthesis, and implant-related complications like exposure and extrusion between the 2 groups.
Results: At a mean follow up of 12.5 months, none of the sockets in group I and 3 (6%) sockets in group II (p = 0.35) had evidence of implant decentration. There were no cases of implant displacement in both groups. The mean implant diameter in group I was 16.97 mm ± 0.65 mm and in group II 19.2 mm ± 0.83 mm (p = 0.0001). Implant extrusion was not different between the 2 groups. The mean custom ocular prosthesis volume in group I was 3.86 ml ± 0.52 ml and in group II 2.50 ml ± 0.68 ml (p < 0.0001).
Conclusions: The rate of nonporous implant migration due to optic nerve disinsertion is not statistically or clinically significant in evisceration with optic nerve disinsertion, allowing placement of a larger implant and fabrication of a custom ocular prosthesis with an ideal weight.
Comment in
-
Re: "Effect of Optic Nerve Disinsertion During Evisceration on Nonporous Implant Migration: A Comparative Case Series and a Review of Literature".Ophthalmic Plast Reconstr Surg. 2018 May/Jun;34(3):300. doi: 10.1097/IOP.0000000000001093. Ophthalmic Plast Reconstr Surg. 2018. PMID: 29734291 No abstract available.
-
Reply re: "Effect of Optic Nerve Disinsertion During Evisceration on Nonporous Implant Migration: A Comparative Case Series and a Review of Literature".Ophthalmic Plast Reconstr Surg. 2018 May/Jun;34(3):300-301. doi: 10.1097/IOP.0000000000001094. Ophthalmic Plast Reconstr Surg. 2018. PMID: 29734292 No abstract available.
Similar articles
-
Re: "Effect of Optic Nerve Disinsertion During Evisceration on Nonporous Implant Migration: A Comparative Case Series and a Review of Literature".Ophthalmic Plast Reconstr Surg. 2018 May/Jun;34(3):300. doi: 10.1097/IOP.0000000000001093. Ophthalmic Plast Reconstr Surg. 2018. PMID: 29734291 No abstract available.
-
Reply re: "Effect of Optic Nerve Disinsertion During Evisceration on Nonporous Implant Migration: A Comparative Case Series and a Review of Literature".Ophthalmic Plast Reconstr Surg. 2018 May/Jun;34(3):300-301. doi: 10.1097/IOP.0000000000001094. Ophthalmic Plast Reconstr Surg. 2018. PMID: 29734292 No abstract available.
-
Evisceration With Implant Placement Posterior to Posterior Sclera.Ophthalmic Plast Reconstr Surg. 2016 May-Jun;32(3):178-82. doi: 10.1097/IOP.0000000000000452. Ophthalmic Plast Reconstr Surg. 2016. PMID: 25811165
-
Different Intraorbital Implant Situations and Ocular Prosthetic Rehabilitation.J Prosthodont. 2016 Dec;25(8):687-693. doi: 10.1111/jopr.12369. Epub 2015 Oct 8. J Prosthodont. 2016. PMID: 26447725 Review.
-
Long-term complications of different porous orbital implants: a 21-year review.Br J Ophthalmol. 2017 May;101(5):681-685. doi: 10.1136/bjophthalmol-2016-308932. Epub 2016 Jul 29. Br J Ophthalmol. 2017. PMID: 27474155 Review.
Cited by
-
Commentary: Assessing the results of anophthalmic prostheses.Indian J Ophthalmol. 2021 Jul;69(7):1881. doi: 10.4103/ijo.IJO_1438_21. Indian J Ophthalmol. 2021. PMID: 34146049 Free PMC article. No abstract available.
-
Low-cost three-dimensional printed orbital template-assisted patient-specific implants for the correction of spherical orbital implant migration.Indian J Ophthalmol. 2018 Nov;66(11):1600-1607. doi: 10.4103/ijo.IJO_472_18. Indian J Ophthalmol. 2018. PMID: 30355870 Free PMC article.
-
Anophthalmic Socket Syndrome: Prevalence, Impact and Management Strategies.Clin Ophthalmol. 2021 Aug 6;15:3267-3281. doi: 10.2147/OPTH.S325652. eCollection 2021. Clin Ophthalmol. 2021. PMID: 34393477 Free PMC article. Review.
-
Safety and aesthetic outcomes of silicone buckles as an implant for anophthalmic sockets: a decade of experience in Japan.Jpn J Ophthalmol. 2025 Mar;69(2):214-220. doi: 10.1007/s10384-025-01164-9. Epub 2025 Feb 7. Jpn J Ophthalmol. 2025. PMID: 39918704 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources