Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Jun;10(6):576-579.
doi: 10.1136/neurintsurg-2017-013259. Epub 2017 Sep 2.

Prediction of hyperperfusion phenomenon after carotid artery stenting and carotid angioplasty using quantitative DSA with cerebral circulation time imaging

Affiliations

Prediction of hyperperfusion phenomenon after carotid artery stenting and carotid angioplasty using quantitative DSA with cerebral circulation time imaging

Keita Yamauchi et al. J Neurointerv Surg. 2018 Jun.

Abstract

Background: Hyperperfusion syndrome after carotid interventions has a low incidence but it can lead to morbidity and mortality.

Objective: To evaluate the usefulness of quantitative DSA for predicting hyperperfusion phenomenon (HPP) after carotid artery stenting and angioplasty.

Methods: Thirty-three consecutive patients with carotid stenosis treated with carotid artery stenting or angioplasty between February 2014 and August 2016 were included. Color-coded digital subtraction angiograms showing the time to maximum contrast intensity of each image pixel were obtained from conventional DSA before and after procedures. The cerebral circulation time (CCT) was defined as the difference in the relative time to maximum intensity between arterial and venous regions of interest set on the angiograms. HPP was diagnosed straight after the procedure with qualitative 123I-IMP single-photon emission CT (SPECT). Cut-off points for detecting HPP for preprocedural CCT and periprocedural change of CCT were assessed by receiver operating characteristic analysis using 123I-IMP SPECT as reference standard.

Results: 123I-IMP SPECT showed HPP in 4 of 33 patients. In these 4 patients, preprocedural prolongation of CCT (13.0±6.1 vs 7.2±1.3 s; p<0.001) was seen compared with patients without HPP as well as larger periprocedural changes of CCT (5.9±5.7 vs 0.5±1.3 s; p<0.001). The optimal cut-off points of preprocedural CCT and change of CCT for predicting HPP were 8.0 s (100% sensitivity, 69% specificity) and 3.2 s (75% sensitivity, 100% specificity), respectively.

Conclusions: Preprocedural prolongation and greater periprocedural change of CCT are associated with the occurrence of HPP. Periprocedural evaluation of CCT may be useful for predicting HPP.

Keywords: angiography; angioplasty; stent.

PubMed Disclaimer

Conflict of interest statement

Competing interests: None declared.

MeSH terms

LinkOut - more resources