Costs Associated With Single-Use and Conventional Sets for Distal Radius Plating

Affiliations

Costs Associated With Single-Use and Conventional Sets for Distal Radius Plating

Bryce Fugarino et al. J Hand Surg Am. 2017 Nov.

Abstract

Purpose: Volar plating of distal radius fractures is an increasingly common procedure. Presterilized, single-use volar plate fixation sets have been purported to increase operating room efficiency and decrease cost. The purpose of this study was to compare the actual cost of using a conventional set compared with the projected cost of using its single-use counterpart.

Methods: We retrospectively analyzed 30 consecutive cases of volar plate fixation in which conventional instrument sets were used. Hardware and processing costs were calculated for the conventional sets and compared with the projected cost of using single-use sets.

Results: The mean total cost of hardware and processing for the conventional sets was $2,728, whereas the projected cost for the single-use sets was slightly higher at $2,868. Twenty-three of the 30 cases would have required additional screws not available in the single-use set. The cost of the additional screws needed to supplement the single-use set would have added an average of $282/case. Overall, the combined hardware and processing cost was lower for conventional sets in 25 of the 30 cases.

Conclusions: Although the price of the single-use set is less than the mean charge for use of a conventional set, additional screws not available in the single-use set were required in 77% of cases and consequently rendered the conventional set cheaper in 83% of cases. Stocking the single-use sets with additional screws to reflect the most commonly used screw lengths could make these sets more cost effective in the future.

Type of study/level of evidence: Economic and decision analysis IV.

Keywords: Cost; distal radius fracture; single-use; volar plate.