Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Winter;8(1):17-21.
doi: 10.15171/jlms.2017.04. Epub 2017 Jan 8.

Effect of Er:YAG Laser and Sandblasting in Recycling of Ceramic Brackets

Affiliations

Effect of Er:YAG Laser and Sandblasting in Recycling of Ceramic Brackets

Soghra Yassaei et al. J Lasers Med Sci. 2017 Winter.

Abstract

Introduction: This study was performed to determine the shear bond strength of rebonded mechanically retentive ceramic brackets after recycling with Erbium-Doped Yttrium Aluminum Garnet (Er:YAG) laser or sandblasting. Methods: Twenty-eight debonded ceramic brackets plus 14 intact new ceramic brackets were used in this study. Debonded brackets were randomly divided into 2 groups of 14. One group was treated by Er:YAG laser and the other with sandblasting. All the specimens were randomly bonded to 42 intact human upper premolars. The shear bond strength of all specimens was determined with a universal testing machine at a crosshead speed of 0.5 mm/min until bond failure occurred. The recycled bracket base surfaces were observed under a scanning electron microscope (SEM). Analysis of variance (ANOVA) and Tukey tests were used to compare the shear bond strength of the 3 groups. Fisher exact test was used to evaluate the differences in adhesive remnant index (ARI) scores. Results: The highest bond strength belonged to brackets recycled by Sandblasting (16.83 MPa). There was no significant difference between the shear bond strength of laser and control groups. SEM photographs showed differences in 2 recycling methods. The laser recycled bracket appeared to have as well-cleaned base as the new bracket. Although the sandblasted bracket photographs showed no remnant adhesives, remarkable micro-roughening of the base of the bracket was apparent. Conclusion: According to the results of this study, both Er:YAG laser and sandblasting were efficient to mechanically recondition retentive ceramic brackets. Also, Er:YAG laser did not change the design of bracket base while removing the remnant adhesives which might encourage its application in clinical practice.

Keywords: Brackets; Ceramic brackets; Er YAG lasers; Recycling; Sandblasting; Shear bond strength.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Figure 2
Figure 2
Figure 3
Figure 3

Similar articles

Cited by

References

    1. Bishara SE, Fehr DE. Ceramic brackets: something old, something new, a review. Semin Orthod. 1997;3(3):178–188. - PubMed
    1. Swartz ML. Ceramic brackets. J Clin Orthod. 1988;22(2):82–88. - PubMed
    1. Chung C-H, Friedman SD, Mante FK. Shear bond strength of rebonded mechanically retentive ceramic brackets. Am J Orthod Dentofacial Orthop. 2002;122(3):282–287. doi: 10.1067/mod.2002.125994. - DOI - PubMed
    1. Britton JC, Mcinnes P, Weinberg R, Ledoux WR, Retief DH. Shear bond strength of ceramic orthodontic brackets to enamel. Am J Orthod Dentofacial Orthop. 1990;98(4):348–353. doi: 10.1016/S0889-5406(05)81492-1. - DOI - PubMed
    1. Bishara SE, Ortho D, Truiove TS. Comparisons of different debonding techniques for ceramic brackets: an in vitro study: Part I Background and methods. Am J Orthod Dentofacial Orthop. 1990;98(2):145–153. - PubMed

LinkOut - more resources