Quantification and Determination of Normal 123I-Meta Iodobenzylguanidine Heart-to-Mediastinum Ratio (HMR) from Cardiac SPECT/CT and Correlation with Planar HMR
- PMID: 28916622
- DOI: 10.2967/jnumed.117.197152
Quantification and Determination of Normal 123I-Meta Iodobenzylguanidine Heart-to-Mediastinum Ratio (HMR) from Cardiac SPECT/CT and Correlation with Planar HMR
Abstract
Assessment of cardiac 123I-meta iodobenzylguanidine (123I-mIBG) uptake relies on the heart-to-mediastinum ratio (HMR) derived from planar images. We have developed novel semiautomated quantitative methodologies for assessing HMR from SPECT images using a dedicated cardiac multipinhole SPECT/CT system and determined the lower limit of normal (LLN) SPECT-derived HMR and the correlation to planar-derived HMR. Methods: Twenty-one healthy volunteers were injected with 123I-mIBG and imaged using 2 different cameras. Planar images were acquired using a conventional SPECT camera equipped with parallel hole collimators, and hybrid SPECT/CT images were acquired using a dedicated cardiac SPECT system with 19 pinhole collimators interfaced with 64-slice CT. Planar HMR was calculated as per standard guidelines (manual traditional method) and elliptic region-of-interest (Elip-ROI) and region-growing (RG-ROI) techniques. SPECT HMR was quantified using a new method that incorporates various cardiac and mediastinal segmentation schemes in which upper and lower limits of the heart were determined from CT and the left ventricular ROI, and mean counts were calculated using Elip-ROI and RG-ROI techniques. Mean counts in mediastinal ROI were computed from a fixed volume in 3 different regions: upper mediastinum (UM), lower mediastinum (LM), and contralateral lung (CL). HMRs were processed by 2 observers, and reproducibility was assessed by intraclass correlation coefficient and Bland-Altman analysis. Results: Planar HMR calculated using the RG-ROI method showed highest intra- and interobserver levels of agreement compared with Elip-ROI and manual traditional methods. SPECT HMR calculated on the basis of UM, LM, and CL background regions showed excellent intra- and interobserver agreement. SPECT HMR with UM resulted in highest correlation (R = 0.91) with planar HMR compared with that with LM (R = 0.74) and CL (R = 0.73). The LLN of SPECT HMR with UM and that of planar HMR was calculated as 5.5 and 1.6, respectively. The normal values of SPECT-derived HMR and planar-derived HMR were correlated linearly. Conclusion: We reconfirmed the previous planar HMR threshold and determined SPECT LLN HMR for SPECT. Planar HMR can be estimated from SPECT HMR via a simple linear regression equation, allowing use of the new cardiac-dedicated SPECT camera for 123I-mIBG imaging.
Keywords: 123I labeled meta-iodobenzyl guanidine; SPECT; heart-to-mediastinum ratio; mIBG quantification; planar.
© 2018 by the Society of Nuclear Medicine and Molecular Imaging.
Similar articles
-
First determination of the heart-to-mediastinum ratio using cardiac dual isotope (¹²³I-MIBG/⁹⁹mTc-tetrofosmin) CZT imaging in patients with heart failure: the ADRECARD study.Eur J Nucl Med Mol Imaging. 2015 Nov;42(12):1912-9. doi: 10.1007/s00259-015-3141-3. Epub 2015 Jul 31. Eur J Nucl Med Mol Imaging. 2015. PMID: 26227533
-
Cardiac 123I-MIBG planar heart to mediastinum ratios depend on patient size; phantom studies suggest SPECT-CT could improve quantification.Biomed Phys Eng Express. 2019 Dec 19;6(1):015011. doi: 10.1088/2057-1976/ab5c09. Biomed Phys Eng Express. 2019. PMID: 33438599
-
Cross calibration of 123I-meta-iodobenzylguanidine heart-to-mediastinum ratio with D-SPECT planogram and Anger camera.Ann Nucl Med. 2017 Oct;31(8):605-615. doi: 10.1007/s12149-017-1191-2. Epub 2017 Jul 8. Ann Nucl Med. 2017. PMID: 28689357 Free PMC article.
-
Standardization of 123I-meta-iodobenzylguanidine myocardial sympathetic activity imaging: phantom calibration and clinical applications.Clin Transl Imaging. 2017;5(3):255-263. doi: 10.1007/s40336-017-0230-2. Epub 2017 May 4. Clin Transl Imaging. 2017. PMID: 28596948 Free PMC article. Review.
-
Mathematical methods to determine quantitative parameters of myocardial 123I-MIBG studies: a review of the literature.Nucl Med Commun. 2010 Jul;31(7):617-28. doi: 10.1097/MNM.0b013e328337a99b. Nucl Med Commun. 2010. PMID: 20220545 Review.
Cited by
-
Anger recall mental stress decreases 123I-metaiodobenzylguanidine (123I-MIBG) uptake and increases heterogeneity of cardiac sympathetic activity in the myocardium in patients with ischemic cardiomyopathy.J Nucl Cardiol. 2022 Apr;29(2):798-809. doi: 10.1007/s12350-020-02372-1. Epub 2020 Oct 8. J Nucl Cardiol. 2022. PMID: 33034036
-
Feasible Classified Models for Parkinson Disease from 99mTc-TRODAT-1 SPECT Imaging.Sensors (Basel). 2019 Apr 11;19(7):1740. doi: 10.3390/s19071740. Sensors (Basel). 2019. PMID: 30978990 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources