Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2017 Nov;2(11):793-804.
doi: 10.1016/S2468-1253(17)30247-9. Epub 2017 Sep 12.

Low-dose CT for the diagnosis of appendicitis in adolescents and young adults (LOCAT): a pragmatic, multicentre, randomised controlled non-inferiority trial

Collaborators
Randomized Controlled Trial

Low-dose CT for the diagnosis of appendicitis in adolescents and young adults (LOCAT): a pragmatic, multicentre, randomised controlled non-inferiority trial

LOCAT Group. Lancet Gastroenterol Hepatol. 2017 Nov.

Abstract

Background: CT radiation is arguably carcinogenic. Results from single-centre studies, mostly retrospective, have advocated lowering the CT radiation dose for the diagnosis of appendicitis. However, adoption of low-dose CT has been slow. We aimed to assess the effectiveness of low-dose CT compared with standard-dose CT in the diagnosis of appendicitis in adolescents and young adults.

Methods: We did this pragmatic, multicentre, randomised controlled non-inferiority trial at 20 South Korean teaching hospitals with little experience with low-dose CT. Patients aged 15-44 years with suspected appendicitis were randomly assigned (1:1), via computer-generated random assignments (permuted block sizes of two, four, six, and eight) concealed in sequentially numbered envelopes, to receive low-dose CT (2 mSv) or standard-dose CT (≤8 mSv). Randomisation was stratified by site. Group allocation was concealed from patients, outcome assessors, and adverse event adjudicators; care providers, site pathologists, and data collectors were aware of allocation. The primary endpoint was the negative (unnecessary) appendectomy rate among all appendectomies, with a non-interiority margin of 4·5% for low-dose versus standard-dose CT. Primary analysis was by modified intention to treat, which included all patients who received an appendectomy in the group to which they were assigned. This trial is registered with ClinicalTrials.gov, number NCT01925014.

Findings: Between Dec 4, 2013, and Aug 18, 2016, we assigned 1535 patients to the low-dose CT group and 1539 patients to the standard-dose CT group. 22 (3·9%) of 559 patients had a negative appendectomy in the low-dose group versus 16 (2·7%) of 601 patients in the standard-dose group (difference 1·3%, 95% CI -0·8 to 3·3; p=0·0022 for the non-inferiority test). We recorded 43 adverse events in 43 (2·8%) of 1535 patients in the low-dose group and 41 adverse events in 40 (2·6%) of 1539 patients in the standard-dose group. One life-threatening adverse event of anaphylaxis caused by an iodinated contrast material occurred in the low-dose group.

Interpretation: Radiation dose of appendiceal CT for adolescents and young adults can be reduced to 2 mSv without impairing clinical outcomes. In view of the vast number of appendiceal CT examinations done worldwide, use of low-dose CT could prevent a sizeable number of radiation-associated cancers in the future.

Funding: Korea Health Industry Development Institute, Seoul National University Bundang Hospital, Dasol Life Science, and Bracco Imaging Korea.

PubMed Disclaimer

Comment in

Publication types

Associated data