CT and MRI Techniques for Imaging Around Orthopedic Hardware
- PMID: 28934809
- DOI: 10.1055/s-0043-118127
CT and MRI Techniques for Imaging Around Orthopedic Hardware
Abstract
Orthopedic hardware impairs image quality in cross-sectional imaging. With an increasing number of orthopedic implants in an aging population, the need to mitigate metal artifacts in computed tomography and magnetic resonance imaging is becoming increasingly relevant. This review provides an overview of the major artifacts in CT and MRI and state-of-the-art solutions to improve image quality. All steps of image acquisition from device selection, scan preparations and parameters to image post-processing influence the magnitude of metal artifacts. Technological advances like dual-energy CT with the possibility of virtual monochromatic imaging (VMI) and new materials offer opportunities to further reduce artifacts in CT and MRI. Dedicated metal artifact reduction sequences contain algorithms to reduce artifacts and improve imaging of surrounding tissue and are essential tools in orthopedic imaging to detect postoperative complications in early stages.
Key points: · Tissues around orthopaedic hardware can still be well visualised despite metal artifacts.. · Artefact reduction in CT: acquisition parameters, iterative reconstruction, Dual-energy CT and VMI.. · Artefact reduction in MRI: choice of device, sequences, acquisition parameters and MARS.
Citation format: · Do TD, Sutter R, Skornitzke S et al. CT and MRI Techniques for Imaging Around Orthopedic Hardware. Fortschr Röntgenstr 2018; 190: 31 - 41.
Orthopädische Implantate verringern die Bildqualität in der Schnittbildgebung. Bei steigendem Einsatz von orthopädischen Implantaten in einer alternden Bevölkerung ist eine Metallartefaktreduktion von zunehmender Bedeutung. Im folgenden Review möchten wir einen Überblick über die wesentlichen Artefakte in der Computertomografie und Magnetresonanztomografie sowie die neuesten Standards zur Verbesserung der Bildqualität geben. Alle Schritte der Bildakquisition von Gerätewahl über Scanvorbereitungen und -parameter bis hin zur Bildverarbeitung beeinflussen das Ausmaß der Metallartefakte. Technische Fortschritte wie die Dual-energy-Computertomografie mit der Option der Virtuellen monochromatischen Bildgebung sowie neue Implantatmaterialien bieten weitere Möglichkeiten der Metallartefaktreduktion in CT und MRT. Dezidierte Metallartefakt-Sequenzen beinhalten Algorithmen zur Artefaktreduktion und zur Verbesserung der Bildqualität des umgebenden Gewebes und sind essenzielle Werkzeuge in der orthopädischen Bildgebung zur frühzeitigen Detektion von postoperativen Komplikationen.
Kernaussagen: · Periprothetisches Weichteilgewebe können trotz Metallartefakte gut visualisiert werden. · Artefaktreduktion in der Computertomographie: Akquisitionsparameter, iterative Rekonstruktionen, Dual-energy CT und VMS. · Artefaktreduktion im MRT: Gerätewahl, Sequenzen, Akquisitionsparameter und MARS.
© Georg Thieme Verlag KG Stuttgart · New York.
Conflict of interest statement
Disclosure The authors report no conflicts of interest in this work.
Similar articles
-
Advances in MRI around metal.J Magn Reson Imaging. 2017 Oct;46(4):972-991. doi: 10.1002/jmri.25708. Epub 2017 Mar 25. J Magn Reson Imaging. 2017. PMID: 28342291 Review.
-
Metal artifact reduction in CT, a phantom study: subjective and objective evaluation of four commercial metal artifact reduction algorithms when used on three different orthopedic metal implants.Acta Radiol. 2018 Sep;59(9):1110-1118. doi: 10.1177/0284185117751278. Epub 2018 Jan 8. Acta Radiol. 2018. PMID: 29310445
-
Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multi-detector CT.Radiographics. 2007 May-Jun;27(3):791-803. doi: 10.1148/rg.273065087. Radiographics. 2007. PMID: 17495293 Review.
-
Managing postoperative artifacts on computed tomography and magnetic resonance imaging.Semin Musculoskelet Radiol. 2011 Sep;15(4):309-19. doi: 10.1055/s-0031-1286013. Epub 2011 Sep 16. Semin Musculoskelet Radiol. 2011. PMID: 21928156 Review.
-
Metal implants on CT: comparison of iterative reconstruction algorithms for reduction of metal artifacts with single energy and spectral CT scanning in a phantom model.Abdom Radiol (NY). 2017 Mar;42(3):742-748. doi: 10.1007/s00261-016-1023-1. Abdom Radiol (NY). 2017. PMID: 28044188
Cited by
-
Dual-layer spectral computerized tomography for metal artifact reduction: small versus large orthopedic devices.Skeletal Radiol. 2019 Dec;48(12):1981-1990. doi: 10.1007/s00256-019-03248-3. Epub 2019 Jun 1. Skeletal Radiol. 2019. PMID: 31154493
-
Single-energy versus dual-energy imaging during CT-guided biopsy using dedicated metal artifact reduction algorithm in an in vivo pig model.PLoS One. 2021 Apr 26;16(4):e0249921. doi: 10.1371/journal.pone.0249921. eCollection 2021. PLoS One. 2021. PMID: 33901200 Free PMC article.
-
Design Considerations to Facilitate Clinical Radiological Evaluation of Implantable Biomedical Structures.ACS Biomater Sci Eng. 2021 Feb 8;7(2):718-726. doi: 10.1021/acsbiomaterials.0c01439. Epub 2021 Jan 13. ACS Biomater Sci Eng. 2021. PMID: 33449622 Free PMC article.
-
Imaging of osteoarthritis from the ankle through the midfoot.Skeletal Radiol. 2023 Nov;52(11):2239-2257. doi: 10.1007/s00256-023-04287-7. Epub 2023 Feb 4. Skeletal Radiol. 2023. PMID: 36737484 Free PMC article. Review.
-
A semi-automated quantitative comparison of metal artifact reduction in photon-counting computed tomography by energy-selective thresholding.Sci Rep. 2020 Dec 3;10(1):21099. doi: 10.1038/s41598-020-77904-3. Sci Rep. 2020. PMID: 33273590 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous