Comparative Study
. 2017 Nov/Dec;38(6):760-766.
doi: 10.1097/AUD.0000000000000496.

Comparison of the Spectral-Temporally Modulated Ripple Test With the Arizona Biomedical Institute Sentence Test in Cochlear Implant Users

Affiliations
Comparative Study

Comparison of the Spectral-Temporally Modulated Ripple Test With the Arizona Biomedical Institute Sentence Test in Cochlear Implant Users

Marshall Lawler et al. Ear Hear. 2017 Nov/Dec.

Abstract

Objectives: Although speech perception is the gold standard for measuring cochlear implant (CI) users' performance, speech perception tests often require extensive adaptation to obtain accurate results, particularly after large changes in maps. Spectral ripple tests, which measure spectral resolution, are an alternate measure that has been shown to correlate with speech perception. A modified spectral ripple test, the spectral-temporally modulated ripple test (SMRT) has recently been developed, and the objective of this study was to compare speech perception and performance on the SMRT for a heterogeneous population of unilateral CI users, bilateral CI users, and bimodal users.

Design: Twenty-five CI users (eight using unilateral CIs, nine using bilateral CIs, and eight using a CI and a hearing aid) were tested on the Arizona Biomedical Institute Sentence Test (AzBio) with a +8 dB signal to noise ratio, and on the SMRT. All participants were tested with their clinical programs.

Results: There was a significant correlation between SMRT and AzBio performance. After a practice block, an improvement of one ripple per octave for SMRT corresponded to an improvement of 12.1% for AzBio. Additionally, there was no significant difference in slope or intercept between any of the CI populations.

Conclusion: The results indicate that performance on the SMRT correlates with speech recognition in noise when measured across unilateral, bilateral, and bimodal CI populations. These results suggest that SMRT scores are strongly associated with speech recognition in noise ability in experienced CI users. Further studies should focus on increasing both the size and diversity of the tested participants, and on determining whether the SMRT technique can be used for early predictions of long-term speech scores, or for evaluating differences among different stimulation strategies or parameter settings.

PubMed Disclaimer

Conflict of interest statement

Conflicts of Interest

We declare no conflicts of interest.

Figures

Figure 1
Figure 1
SMRT scores significantly correlate with AzBio in noise scores. Each data point represents one participant. The solid line reflects a linear fit of the data from the current study. The dashed line reflects a linear fit of the data from Holden et al. (2016).
Figure 2
Figure 2
Electrodograms (top panel) and acoustic signals (bottom panel) for SMRT stimuli demonstrating the effects of increased ripple density on the amplitude modulation in different frequency bands.
Figure 3
Figure 3
Electrodograms (top panel) and acoustic signals (bottom panel) for SMRT stimuli demonstrating the effects of increased spectral smearing on the amplitude modulation in different frequency bands. For the electrodograms, channels were slightly shifted in time to align pulses across channels so they could be added together.

References

    1. Anderson ES, Nelson DA, Kreft H, et al. Comparing spatial tuning curves, spectral ripple resolution, and speech perception in cochlear implant users. J Acoust Soc Am. 2011;130:364–375. - PMC - PubMed
    1. Aronoff JM, Landsberger DM. The development of a modified spectral ripple test. J Acoust Soc Am. 2013;134:EL217–22. - PMC - PubMed
    1. Aronoff JM, Padilla M, Stelmach J, et al. Clinically Paired Electrodes Are Often Not Perceived as Pitch Matched. Trends Hear. 2016a:20. - PMC - PubMed
    1. Aronoff JM, Stelmach J, Padilla M, et al. Interleaved Processors Improve Cochlear Implant Patients’ Spectral Resolution. Ear Hear. 2016b;37:e85–e90. - PMC - PubMed
    1. Chi T, Gao Y, Guyton MC, et al. Spectro-temporal modulation transfer functions and speech intelligibility. J Acoust Soc Am. 1999;106:2719–2732. - PubMed

Publication types