Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2018 Apr 1;91(5):975-983.
doi: 10.1002/ccd.27340. Epub 2017 Sep 30.

Transcatheter aortic valve replacement for stenotic bicuspid aortic valves: Systematic review and meta analyses of observational studies

Affiliations
Meta-Analysis

Transcatheter aortic valve replacement for stenotic bicuspid aortic valves: Systematic review and meta analyses of observational studies

Gautam Reddy et al. Catheter Cardiovasc Interv. .

Abstract

Objective: The aim of this study was to perform a systematic review and meta-analyses of observational studies of transcatheter aortic valve replacement (TAVR) for bicuspid aortic valve stenosis (BcAV).

Background: TAVR for BcAV stenosis has been associated with an increased incidence of paravalvular leaks, valve malposition, pacemaker placement and all-cause mortality. The conclusions drawn have been limited by small sample sizes. The use of TAVR for BcAV stenosis remains controversial.

Methods: We searched multiple databases from the inception of the databases through September 30, 2016 for studies of TAVR for BcAV stenosis. We included all observational studies with more than one patient and at least 1 month of outcomes.

Results: We analyzed 13 observational studies with 758 patients. Meta analyses showed device success rate of 95% [95% confidence interval (CI) 90.2% to 98.5%] and an early safety event in 16.9% [95% CI 12.2% to 22%]. At 30 days, moderate to severe paravalvular leak was seen in 12.2% [95% CI 3.1% to 24.8%] and new pacemaker implantation in 17.9% [95% CI 14.2% to 22%]. All-cause mortality was 3.7% [95% CI 2.1% to 5.6%], which should be viewed in the context of an STS PROM of 5.0%.

Conclusions: This analysis suggests that TAVR for BcAV is not associated with excess mortality. The incidence of paravalvular leaks and pacemaker implant is increased compared to tricuspid aortic valve cohorts undergoing TAVR, and operators should weigh these potential complications against the clinical benefit provided by TAVR for BcAV patients at high risk for surgical valve replacement.

Keywords: aortic stenosis; bicuspid valve; meta analysis; transcatheter valve.

PubMed Disclaimer

Comment in

MeSH terms

LinkOut - more resources